F5 (SETUP) Screen: PARAMETER
F1 : M_MENU F2 : A_MARK F3 : EDIT F4 : FILE
F5 : SETUP F6 : TEST F7 : LOAD F8 : COMM
MARK SPEED [ 02000 ]
USE PLC SEQUENCE TABLE ? [ Y ]
ECHO MARK DATA TO HOST ? [ Y ]
MOVE X THEN Y TO OFFSETS ? [ Y ]
MOVE Y THEN X TO HOME ? [ Y ]
[ SETUP MODE]
CUSOR_MOVE : ENTER F5 : DATE CODE SET
MOVE SPEED [ 10000 ] ACCEL. RATE [ 100 ].
X MOTOR [ 10000 ] STEPS/100MM.
Y MOTOR [ 10000 ] STEPS/100MM.
SOL. DN DLY [ 10000 ] SOL. UP DLY [ 10000 ]
END OUT DLY [ 00150 ]
MARK SPEED [02000]: Real speed of marking pin. Make use of extent: 00500~ 05000 standards: 2000
MOVE SPEED [10000]: Moving speed except for marking. Make use of extent: 05000~10000 Standard: 6000
ACCEL.RATE [0100]: Acceleration rate of motor is [0100] or [00500]
X MOTOR [10000] steps/100mm. : Standard: 10000purse per 100mm
Y MOTOR [10000] steps/100mm. : Standard: 10000purse per 100mm
If you modify this value, stored letter size, interval, and moving distance were changed.
*Don`t adjust them*
SOL. DN DLY [00002]: PIN UP DELAY (SOL.OFF DELAY):2.
SOL. UP DLY [00002]: PIN DOWN DELAY (Delay the motor movement after SOL.ON. adjust between 2 to 12)
END OUT DLY [00150]: As finished signal, It`s time to be indicated that Relay ON for a half second.
Use PLC sequence table? [Y]
Echo mark data to host? [Y] When be marking on the communicate mode, it sends the marking data to host.
Move X then Y to offsets? [Y] Select the marking moving order during pin is progressing
Move Y then X when homing? [Y] Select the marking moving order during pin is returning
Press the enter key constantly until item that select returning order and then press
“
ENTER
“
key again,
you can change the data of a desk schedule. .
F1 : M_MENU F2 : A_MARK F3 : EDIT F4 : FILE
F5 : SETUP F6 : TEST F7 : LOAD F8 : COMM
TEAM CODE
[ DATE CODE SET ]
CUSOR_MOVE : ENTER F5 : MOTOR/OPTIONS
1.[ A ] = FROM [00:00:00] TO [07:59:59]
2.[ B ] = FROM [00:00:00] TO [07:59:59]
3.[ C ] = FROM [00:00:00] TO [07:59:59]
4.[ ] = NO 4TH SHIFT
5.[ ] = NO 5TH SHIFT
6.[ ] = NO 6TH SHIFT
7.[ ] = NO 7TH SHIFT
8.[ ] = NO 8TH SHIFT
25
Содержание Marksman MK-100N
Страница 5: ...Accessories Common CABLE Cable 15M CDC 20 Dip switch New NF 8785 T 300 5 ...
Страница 6: ...MARKING PIN LP 06 LP 10 LP 15 PH 16 LP 10 pin for Gun PLP 10 DIA_90D 6 ...
Страница 39: ...2 If you check on the Plot to file the file name will be archived 3 Create Plot file Set up the file name 39 ...
Страница 50: ...Advance programming 50 ...