General maintenance
Use the dry air without the high moisture
Check the putting to earth ground
Check the connection of connector
Be careful of the trespass of paint, metal chip & dust into MCU
Checking the exhaust fan & filter
Increase of misprint, check in the pin assembly.
Servicing the Marksman
Can not start the MCU (Main control unit):
Check S/W & lamps on the front panel see page
–
5-
Check it the
“
mark up to [00000000] is all zero in the F2 screen
Check the F6 test mode
LCD display problem:
If the LCD displays the misspell or the cursor moves by one self,
Please clear all memory on the front panel, and input the data, and again start the machine.
If it has a still problem, check the main control board or contact our distributor immediately.
Lost the X/Y: coordinates
When the machine lost the inputted X/Y coordinator values, is this location error continuously every
time?
If yes, please check the X/Y values again and try to the memory clear.
If you still have same problem, please check the other controller near MCU.
This will be an electrical noise problem and check again by electrician.
Check the mechanism of the X/Y-moving system:
Please check all connection of X/Y-axis motor and driver
Check the timing pulley and belts, motors and support bolt of pulley.
, If the misspelling, please check pulley assembly.
If the motor stop, check a motor driver, motor and DC24volt power supply
43
Содержание Marksman MK-100N
Страница 5: ...Accessories Common CABLE Cable 15M CDC 20 Dip switch New NF 8785 T 300 5 ...
Страница 6: ...MARKING PIN LP 06 LP 10 LP 15 PH 16 LP 10 pin for Gun PLP 10 DIA_90D 6 ...
Страница 39: ...2 If you check on the Plot to file the file name will be archived 3 Create Plot file Set up the file name 39 ...
Страница 50: ...Advance programming 50 ...