e53
PIR /PIT/POU movement detector not detecting a person’s moviment
1 Ensure that the detector has been enrolled in the control panel.
2 Ensure that the battery of the detector is full and securily connected. Refer to pag111
3 Ensure that the detector is within effective radio range of the control panel and is not
mounted close to objects which may interfere with RF transmission.Refer to pag111
4 Ensure that the detector is mounted at the correct height (i.e. 2-2,5m) and the lense is
oriented torward the floor.
5 Allow up to 3 minutes for the detector to stabilize and become fully operational.Leave the
area for this period.
6 Pulse count set too high -reset to one pulse detection. (refer to the detector ’s manual).
Magnetic contact sensor DW not working
1 Ensure that the detector has been enrolled in the control panel.
2 Ensure that the battery of the detector is full and securily connected and the led lights up.
3 Ensure that the detector is within effective radio range of the control panel and is not
mounted close to objects which may interfere with RF transmission.Refer to pag111
4 Ensure that the magnet is correctly positioned in relation to detector and that the gap
between magnet and detector is not too large (max: 10mm).
Magnetic contact sensor DW
1 Ensure that the detector is within effective radio range of the control panel and is not
mounted close to objects which may interfere with RF transmission.
2 Ensure that the magnet is correctly positioned in relation to detector and that the gap
between magnet and detector is not too large (max: 10mm).
false alarming
Magnetic contact sensor Led does not light up when opening the window.
1 Low battery - replace the battery.
2 The detector does not work -replace the detector.
Refer to pag111
PIR /PIT/POU movement detector false alarming
1 Ensure that the detector is not pointing at a source of heat or a moving object.
2 Ensure that the detector is not mounted above a radiator or heater.
3 Ensure that the detector is not facing a window or in direct sunlight.
4 Ensure that the detector is not in a draughty area.
5 Pulse count set too low - reset to two pulse detection.(refer to the detector ’s manual)