15
JREMO 10K
Industrial radio remote controller
CHAPTER 5. TROUBLESHOOTING
5-1 SELF DIAGNOSIS (LED SIGNAL ERROR MESSAGE)
JEICO
remote controllers have a renewed method of self diagnostic trou-
bleshooting against so much complicated and riddled electronic struc-
tures, and yet it is easy to check and find causes and measures for any
malfunctions may occur.
JEICO
takes a type of Led signaling error message
for better, quick restoration in normal even at site.
CHAPTER 5. TROUBLESHOOTING
5-2 LED Diagnosis
Causes
LED Signals
Measures
Transmitter
(TX)
EMS Button not up
Red Light
Pull up EMS Button
Rotary S/W not ON
Red Light
Set to ON position
Push Button defect
Red Flash
Replace with new button(s)
Encoder Module defect No Signal
Replace with a new module
Batteries Consumed
No Signal
Replace with new batteries
Low Power
Red & Green
Flashes
Replace with new batteries
Receiver
(RX)
Decoder defect
Lamp Off
Replace with a new Rx/Rf
Wrong Power Source
Lamp Off
Replace Fuses and/or
Replace Relay Board
Connect Right Power
Main Relay defect
Lamp Off
Replace Main Relay
Rx-Rf COPY position
Lamp Off
Set to RUN position
Main Power Off
Lamp Off
Engage Main Power