Appendix A
Specifications
OLP-3057 specifications
32
HST-3000 OLP-3057 Optical Power Meter User’s Guide
OLP-3057 specifications
provides the specifications for the OLP-3057 SIM.
Table 9
Optical specifications
Item
Description
Measurement of 1310 nm (upstream)
Pass band
Isolation of 1490/1550 nm bands
1
Max. permitted input level
Measurement range
1260 to 1360 nm
>50 dB
+17 dBm
Burst: +10 to –35 dBm
Measurement of 1490 nm (downstream)
Pass band
Isolation of 1550 nm band
Isolation of 1310 nm band
Max. permitted input level
Measurement range
1480 to 1500 nm
>50 dB
>50 dB
+15 dBm
+10 to –50 dBm
Measurement of 1550 nm (downstream)
Pass band
Isolation of 1490 nm band
Isolation of 1310 nm band
Max. permitted input level
Measurement range
1530 to 1570 nm
>50 dB
>50 dB
+26 dBm
+26 to –50 dBm
Broadband wavelength
Calibrated wavelength
850nm/1310nm/1550nm/1625nm
Modulation detection
(Broadband mode)
For frequencies
270Hz, 330Hz, 1kHz, 2kHz
Automatic wavelength detection
(Broadband)
In combination with OLS-5, OLS-6, OLS-55, or
OLS-56
In power level rate:
800 to 1299nm and 1551 to 1650 nm
1300 to 1550 nm
-45 to +5 dBm
-50 to +5 dBm
Содержание HST-3000 OLP-3057
Страница 1: ...HST 3000 OLP 3057 FTTx PON Selective Optical Power Meter User s Guide...
Страница 2: ......
Страница 3: ...HST 3000 OLP 3057 FTTx PON Selective Optical Power Meter User s Guide...
Страница 10: ...Contents viii HST 3000 OLP 3057 Optical Power Meter User s Guide...
Страница 18: ...About This Guide Technical assistance xvi HST 3000 OLP 3057 Optical Power Meter User s Guide...
Страница 30: ...Chapter 2 Connections Connecting to the line 12 HST 3000 OLP 3057 Optical Power Meter User s Guide...
Страница 53: ......