background image

Auto-Calibration

Error Conditions Chart

Look at the indicator LED connected to the test

harness, or the bezel light.  If the LED blinks from 1 to

11 times at 1/2 second intervals, an error exists.

Count the number of blinks and match with the list

below.  If you missed the count, it will repeat after a 1-

second pause.

# of
Blinks

Error Found During Calibration

1

2

3

4

5

6

7

8

9

10

11

Entrance Lever Error

Solenoid Error

Entrance Sensor Error

Transport Jam

Gain Error - White or Black Level

Digital/Analog Error

Bar Code Sensor Error

Acceptor Head Error

Magnetic Setting Error

Write-in Error

Black Level Error

Содержание WBA

Страница 1: ...ifica tions with advancements in technology For further detailed information pertaining to procedures and troubleshooting methods please contact our Technical Support Division of Customer Service Tech...

Страница 2: ...lution Check game options Set credit limit for proper acceptance Check and verify cashbox condition Calibrate unit using proper procedures Check for proper software ID protocol No Activity No power to...

Страница 3: ...Specifies any of the 8 sub tests to check sensors in the Transport To test the ability to accept bills without using the cashbox attached To test the ability to accept bills and stack using the cashb...

Страница 4: ...hbox WBATM Units 1 Set Dip switch 8 to the ON position all others to the OFF position This puts the unit in Test Mode 2 Apply power connector 3 Select a Test Mode from the list below and set the Dip s...

Страница 5: ...sport Sub Sensor Test Troubleshooting Tests 1 2 3 4 5 6 7 8 Feed in Sensor X Solenoid Lever Sensor X Feed out Sensor X Stacker Home Sensor X No Cashbox Sensor X Validator Encoder Sensor X Stacker Enco...

Страница 6: ...r not working Stacker encoder gear blade split Stacker may be jammed or blocked Cover open Stacker lever problem Something blocking the sensors Sensor problem Acceptor head not seated properly Communi...

Страница 7: ...ensor PT3 or PT4 not working Bill inserted crooked Dirty rollers belts Bad mag sensor PCB Sensor other than PT1 PT2 or PT3 PT4 de tected the presence of the bill note while in stand by Reflective sens...

Страница 8: ...pressed air via can or air compressor to blow out paper fibers and any other debris that may build up over time Check the belts and all moving parts for wear and proper positioning If this assembly do...

Страница 9: ...are Off 4 way acceptance if within firmware I F On ID 022 Off ID 023 Dir On 2 way acceptance if within firmware Off 4 way acceptance if within firmware WBA 10 11 12 13 ID 022 023 IGT WBA 10 11 12 13 I...

Страница 10: ...the calibration paper black paper first the unit will carry the paper forward reverse several times When the process is complete the unit will return the paper 6 Wait a few moments to allow for comple...

Страница 11: ...he number of blinks and match with the list below If you missed the count it will repeat after a 1 second pause of Blinks Error Found During Calibration 1 2 3 4 5 6 7 8 9 10 11 Entrance Lever Error So...

Страница 12: ...through or be rejected If it rejects check calibration Re calibrate if necessary If the unit still rejects there is a possible sensor problem or incorrect software version Go to Bill Return Tests page...

Страница 13: ...m DT 004 to WBA unit Note The PS15 007 can be used to substitute for a power source instead of using the harness Part No 400 100068 at the game When there is an RS 232 board disconnect the board and u...

Страница 14: ...the RESET button once then press the VERIFY button once After approximately 10 seconds a buzzer will sound for about a second and the OK LED will illuminate 11 Turn power on the DT 004 to the OFF posi...

Страница 15: ...Standard Aristocrat Atronics Bally CDS Sigma VLC and WMS ID 022 023 IGT S Slots P E P E Plus ID 024 IGT Game King I Game and Vision Series DBV I F ID Interface OEM Gaming Manufacturer ID 004 Bar JCM S...

Страница 16: ...tern Region 3000 Dundee Road Ste 402 Northbrook IL 60062 Office 847 418 3354 Fax 847 418 3357 Eastern Region 3 Canale Drive Ste 4 Egg Harbor NJ 08234 Office 609 677 8909 Fax 609 677 8820 Southern Regi...

Отзывы: