12V dc supply
1
Magnetic detector contact channels 1 and 3
-
12V dc supply
2
Magnetic detector contact channels 2 and 4
S
Decoded signal output (C4+ / Clock / D0 Wiegand)
3
Contact common
D
Decoded signal output (Data / D1 Wiegand)
Introduction
--------------------------------------------------------------------------
EN
Wiegand interface compatible with DCS range transmitters. Decodes in four different protocols according to its configuration:
C4+, Clock&Data, Wiegand 26 and Wiegand 37.
Technical Data
Power supply
12V dc
Frequency
433.92MHz
Consumption
12.6mA
Sensitivity
Better than –100dBm
Antenna
Incorporated, adjustable
Operating temperature
-20ºC / +85ºC
Watertightness
IP54
Dimensions
127x70x52mm
Weight
143g
Installation
Disconnect the power supply before handing the installation in the receiver.
Fitting the casing
The receiver is made up of 4 different parts: a rear cover, a circuit, a curved front cover and an adjustable aerial.
•
Secure the circuit to the rear cover.
•
Insert the wiring through the holes made for this purpose on the rear cover.
•
Fit the rear casing cover to the wall using the rawlplugs and screws supplied.
•
Slide the front of the receiver along the guide on the rear cover.
•
Screw the aerial into the top of the casing.
Operating
Configuration and connection for the different protocols
Protocol
Power
supply
Signal outlet
SW1 PROTOCOL SW2 PROTOCOL
Format
C4+
+ -
S
OFF
OFF
---
Clock&Data
+ -
S=CLOCK and D=DATA
OFF
ON
8 BCD digits
Wiegand 26
+ -
S=D0 and D=D1
ON
OFF
8 fix bits + 16 code bits
Wiegand 37
+ -
S=D0 and D=D1
ON
ON
---