8.
Using the MAG tool
When the first part of the adjustment is done, the the magnetic sensors need to be
callibrated. In order to do this, please use the JCM-G MAG Tool (fig 13).
After switching on the MAG tool, insert the green board, as far as the label.„WBA
1x/2x“, into the head unit. The board needs to be moved forwards and backwards
until the software recognizes the maximum amplitude. Click on ENTER and do not
move the board. The WBA is adjusted within a few seconds.
Fig. 13