Lecture Notes
July, 2013
F
EED
M
OTOR
R
EVERSE
R
OTATION
T
EST
Perform the following steps to test the normal reverse rotation functionality of
the Feed Motor:
1. Ensure the VEGA's Power is
OFF
.
2. Set DS1, Switches #1, & #2
ON
.
3. Apply Power to the VEGA.
4. Set DS1, Switch #1 OFF. This begins the Feed Motor Reverse Rotation Test.
5. If the Feed Motor rotates in reverse correctly, the Front Panel LED will remain
extinguished (Out) and reverse rotation will continue.
6. To end the test, set DS1, Switch #1
ON
.
S
TACKER
M
OTOR
T
EST
Perform the following steps to test the Stacker motor functionality:
1. Ensure the VEGA's Power is
OFF
.
2. Set DS1, Switches #1, & #3
ON
.
3. Apply Power to the VEGA.
4. Set DS1, Switch #1
OFF
. This begins the Stacker Motor Test.
5. If the Stacker Motor rotates correctly, the Front Panel LED will remain extin-
guished (Out) and the Motor will continue operating.
6. To end the test, set DS1, Switch #1
ON
.
Table 6
Stacker Motor Error Codes
LED Color Blink Sequence
Error Indication
RED
5
Cash Box Seating Problem
PURPLE
5
Stacker Motor Lock-up
7
Stacker Motor Gear Problem
ORANGE
3
Stacker Full
NOTE: If the Front Panel LED blinks any white sequence in Table 3, the Feed
Motor Reverse Rotation is abnormal.
NOTE: If the Front Panel LED blinks any error sequence listed in Table 6, the
Stacker Motor's Rotation is abnormal.