© 2013, JCM American, Corporation
1 0
Lecture Notes
July, 2013
DIP SWITCH SETTINGS
The VEGA Banknote Validator contains three (3) DIP Switch Blocks (i.e.,
DS1, DS2, and DS3). They are located in the center of the top of the Unit
approximately two (2) inches from the front of the Unit (Review Figure 2
h
).
•
DIP Switch Block DS1 is used to select Test Mode, and to select the desired
Banknote Acceptance/Inhibit settings shown in Table 2.
•
DIP Switch Block DS2 is used to select between the desired Communications
Interface Protocols shown in Table 3.
•
DIP Switch Block DS3 selects between the RS232C and Pulse Interface Com-
munication Protocols shown in Table 4.
Table 4
DIP Switch Block 3 Settings
Switch
No.
Switch ON
Switch OFF
1
RS232C Interface
Pulse Interface
Table 2
DIP Switch Block 1 Settings
Switch
No.
Switch ON
Switch OFF
1
Test Mode
Basic
Performance
2
Refer to the Related Country’s
Software Specification Sheet
3
4
5
6
7
8
DS1
Table 3
DIP Switch Block 2 Settings
Switch
No.
Switch ON
Switch OFF
1
Refer to the Related Country’s
Software Specification Sheet
2
3
4
5
6
7
8
DS2
6
7
8
IF Setting
OFF
OFF
OFF
ID-003 Serial (RS-232C)
OFF
ON
ON
ID-003 (Photo-Coupler
Isolation)
OFF
ON
OFF
ccTalk (Non-Encrypted)
ON
ON
OFF
ccTalk (Encrypted)
ON
OFF
ON
ccTalk (Simple
Checksum)
ON
OFF
OFF
MDB
DS3
1 (ON)
2 (OFF)