background image

Installation Manual

JBL Professional Intellivox - High Power series 

Models Ivx HP-DS170 and Ivx HP-DS370

(Part Nos. 587870 & 587890)

Содержание Ivx HP-DS170

Страница 1: ...Installation Manual JBL Professional Intellivox High Power series Models Ivx HP DS170 and Ivx HP DS370 Part Nos 587870 587890...

Страница 2: ...January 2016 USER S NOTICE AND DISCLAIMER No part of this manual including the software described in it may be reproduced transmitted transcribed stored in a database system or translated without the...

Страница 3: ...uide 7 Preparing For Installation 7 Signal And Control Cables 7 Connector And Wiring Details 9 AC Mains 10 Audio Inputs 11 Network Connection 13 Fault Monitoring 14 Status LED 16 Mechanical Installati...

Страница 4: ...rer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid...

Страница 5: ...plifier and loudspeaker should be tested for basic functionality using the supplied JBL WinControl software the manual also describes this procedure Note that full configuration and control of the lou...

Страница 6: ...bracket fixings E Nylon cable ties 98 x 2 5 mm 5 Strain relief for connectors Items F J F 3 pin 3 81 mm pitch screw terminal female connectors with cover 3 Audio Line Input 1 G Audio Line Input 2 H Fa...

Страница 7: ...ier Refer to the datasheet supplied for the actual figures specific to the model being installed The third terminal of the mains outlet must be connected to a proper safety ground Local safety regulat...

Страница 8: ...th two individually foil screened twisted pairs should be used Details of suitable cables can be found at Network Cables on page 24 Audio inputs the Intellivox accepts line level audio 0 dBV Two separ...

Страница 9: ...ent noise sensing microphone as it could compromise the IP rating of the product Warning to maintain IP rating these cable entry holes must be fitted with a suitable IP rated cable gland Connector Bay...

Страница 10: ...red as per the table below TERM USE EURO USA 1 PE Protective Earth Green yellow Green 2 N Neutral Blue White 3 L Live Brown Black Fit the lower half of the connector cover to the connector ensuring th...

Страница 11: ...ating connectors are supplied with the unit The inputs should be wired as follows Screen Cold Black UK or White US Hot Red UK or Blue US If the Intellivox is being fed from equipment whose outputs are...

Страница 12: ...techniques that may be applied in order to reduce ground induced noise To minimize hum and noise pickup balanced analogue interconnections between audio sources and the Intellivox should always be us...

Страница 13: ...twork repeater will be required Further information on the RS 485 network can be found in the manual for the USB to RS 485 converter and in the WinControl Help files Before connecting multiple devices...

Страница 14: ...sensing line monitoring equipment such as the AXYS Cerberus This selection is made by moving PCB jumper K7 located on the input board see Fig 13 on page 15 for location Volt free mode In volt free op...

Страница 15: ...failure monitoring scheme requiring no additional connections can be easily implemented This is based on impedance switching The amplifier driving this input should be capable of detecting changes in...

Страница 16: ...4 providesstatusinformationabouttheelectronics section and various abnormal operating conditions that may arise Under normal operating conditions the display will show 0 The codes are as follows DISPL...

Страница 17: ...his position that must correspond to the operational height defined in the design process Note that the horizontal position of the acoustic centre is on the vertical centre line of the column When cal...

Страница 18: ...hreaded insert at the top of its enclosure This should only be used for lifting during installation and should NOT be used as a permanent fixing point There are three options for mounting the Intelliv...

Страница 19: ...of acoustic resonances see below Cavity walls can sometimes be problematical when high power loudspeakers are mounted on them The internal wall cavity may resonate at one or more frequencies degrading...

Страница 20: ...panner but stop with a few mm of screw shaft visible between the head and the wall 4 Check that it is possible to slide a bracket over the heads 5 Check that the chosen mounting points will position t...

Страница 21: ...re included with the interface itself CONNECTING THE PC TO THE INTELLIVOX The PC connects to the Intellivox via an RS 485 interface adapter A cable to connect the RS 485 interface adapter to the Intel...

Страница 22: ...open a further Open dialogue box Navigation may be continued in the normal Windows manner Note that Intellivox settings files always have an ini file extension Select the correct settings file and cl...

Страница 23: ...ES Listed below are a number of additional components which may be required for an individual installation Other installation reated accessories Network Accessories DESCRIPTION ORDER CODE Serial inter...

Страница 24: ...tors These GND pins are for connecting the screen shield of the audio cables The RS 485 connector has one pin marked DGND and is intended as a terminal for the network cable screen shield Since the RS...

Страница 25: ...25 201601 IvxHPIM_v1 2 JBL Intellivox HP series Installation Manual Rev 1 2...

Страница 26: ...JBL Professional 8500 Balboa Boulevard Northridge CA 91329 U S A Copyright 2016 JBL Professional www jblpro com...

Отзывы: