12
Do not press
the tool button while tinning the desoldering tip, as the fumes given
off by the flux would quickly block the ducts and the air filter.
General Maintenance
- Before carrying out maintenance, always unplug the stand and the tool. Allow the equipment to
cool down.
- Check periodically that the metal parts of the tool and the stand are clean to ensure detection of
the tool when it is in the stand. Use a damp cloth or alcohol.
- Periodically check all cables and tubes connections.
- The wool, filter and gaskets of the solder-collector should be periodically checked and replaced
when worn or clogged with solder residues.
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
- Before storing the equipment, remember to tin the tips to prevent oxidation.
Clean periodically
Maintenance
Clean periodically