17
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - color gris
200 mm
300 mm
B0001
Grips for B115/B210 Handles
1. Cutting
2. Removing
B210
Precision Handle for B·IRON
Replacing Grips
Make a length-ways cut on the worn grip.
Be careful not to damage the handle.
Remove the worn grip.
Assembling New Grips
Firmly slide the grip onto the handle until it locks into place.
Cutter
Replacing Sealing Plugs
The sealing plug prevents undesirable flux vapors or particles from entering the handle. Its usage is
highly recommended for intensive applications when soldering is exposed to FOD environments or
for applications where the soldering iron works close to a vertical position.
Note:
Choose the correct sealing plug depending
on your handle model.
Before replacing the sealing plug, disconnect the
tool from the station and make sure the device is
not hot.
Handle
Sealing Plug
B210
OB4000
B115
OB5000