background image

Tip Cleaner

Select the option that best suits your needs and improve the tip thermal transfer.

CL0301

Wiper for B·IRON Charging Base

CL0301 includes an antisplash area that

 

prevents solder 

particles from splashing onto the working area, keeping 

the workplace clean.

 

It also includes a temperature-resistant wiper for 

removing excess solder by gently tapping or wiping 

the cartridge tip on it.

If the tip is very dirty, JBC recommends cleaning it first 

with the wiper to remove excess solder and then with 

the brass wool.

CL0300

Brass Wool for 

B·IRON

Very effective 

cleaning method. 

Leaves a small layer 

of solder on the tip 

preventing oxidation 

between cleaning 

and rewetting.

Tap gently to remove excess solder.

Use the slots to remove remaining particles.

Wiper

Tapping

Wiping

Reference Mark

Reference Mark

*Inserting C210 Cartridges

Push the cartridges inside the handle until the 
the reference mark is aligned with the edge 
of the handle.

Reference Ring

Reference Ring

*Inserting C115 Cartridges

Push the cartridges inside the handle until the 
reference ring rests against the sealing plug.

Holes

Depending on the shape of the tip, use the holes on the sides of the cartridge exchanger to 
properly adjust the cartridge.

Important: 

Push the cartridge in as far as it will go, making sure that it is firmly assembled*.

3. Fixing Cartridges

Cartridge Holder

for C210 Cartridges

The cartridge holder (4x slots) is used to 
store cartridges. It allows to have different 
cartridges quickly at hand and it works with 
C210 Cartridges.

Cartridge Holder 

Slots

Cartridge Adapters

for C115 Cartridges

Since C115 cartridges have a smaller diameter 
than C210 cartridges, adapters must be used 
to store them in the cartridge holder.
These adapters must simply be inserted from 
above into the slots of the cartridge holder.

Cartridge 

Adapter

14

Содержание B-IRON 210 DUAL

Страница 1: ...INSTRUCTION MANUAL Battery Powered Soldering Station B IRON 210 DUAL...

Страница 2: ...its Ref B210 C Includes Safety Cap for B115 B210 Handles ref 0031596 Portable Display 7 for B IRON 1 unit Ref PDS B C210 Cartridge 2 units Ref C210001 tip 0 3 mm This manual corresponds to the followi...

Страница 3: ...embled in the stand Power Cord 1 unit Ref 0027380 120V N America Taiwan 0027381 230V India 0027382 230V Europe 0027378 230V United Kingdom Manual 1 unit Ref 0030315 USB Cable USB A to USB C 1 unit Ref...

Страница 4: ...ridge Exchanger CL0300 Brass Wool for B IRON inside Adjustable Tool Holder and Charger Cartridge Holder Antisplash Membrane Adjustable Tool Holder and Charger PDS Portable Display 7 for B IRON Please...

Страница 5: ...Connector USB Cable Ref 0028092 B210 Precision Handle for B IRON C210 Cartridge Range Bluetooth Connection Safety Cap Holder C210 Cartridge Range Bluetooth Connection Display Support Holder for Portab...

Страница 6: ...tion 3 Display Placing Insert the thin end of the display holder into the upper area of the rear rail of the charging base 1 Then carefully rotate the display holder 90 degrees 2 until it stands verti...

Страница 7: ...forward or backward 1 to the desired working position 2 Tool holders have 7 different positions each varying by an angle of 10 degrees Do not rotate the tool holder with a tool resting on it Note The...

Страница 8: ...lder 4 to charge it A beep will sound to con rm that the tool is properly placed and charging The sound can be turned up down or off using the buttons on the display Note Charge the tool completely be...

Страница 9: ...he cartridge stops heating immediately data transfer is cut off and the tool is disconnected from the station It turns off completely after 10 minutes of inactivity This allows a greater saving of the...

Страница 10: ...de When the tool is lifted from the tool holder the tip of the assembled cartridge will heat up to the selected working temperature While the tool remains on the tool holder it charges and the tip wil...

Страница 11: ...ider Temperature Scale Power Scale Graph and Automatic Data Display The graph display of the temperature and supplied power starts automatically as soon as the tool is lifted from the charging base Th...

Страница 12: ...ted from the tool holder and the graph is automatically displayed again at the point where the previous display stopped leaving a small gap on the graph between the last registered value and the new s...

Страница 13: ...fore protected The cartridge exchanger of B IRON stations works with C210 and C115 cartridges Cartridge Retention The cartridge exchanger saves time and allows to change cartridges safely without swit...

Страница 14: ...adjust the cartridge Important Push the cartridge in as far as it will go making sure that it is firmly assembled 3 Fixing Cartridges Cartridge Holder for C210 Cartridges The cartridge holder 4x slot...

Страница 15: ...xcess solder by gently tapping or wiping the cartridge tip on it If the tip is very dirty JBC recommends cleaning it first with the wiper to remove excess solder and then with the brass wool CL0300 Br...

Страница 16: ...o the charging base Make sure that the brass wool is on the far left and that there is space for the wiper on the right Press the wiper down at the 4 corners until you feel it click into place Make su...

Страница 17: ...l it locks into place Cutter Replacing Sealing Plugs The sealing plug prevents undesirable flux vapors or particles from entering the handle Its usage is highly recommended for intensive applications...

Страница 18: ...ed Side Tool Holder Dissasembly and Replacement Adjustable tool holders can be disassembled by loosening the screws 1 at the bottom of the charging base and pulling downward from the side band 2 Befor...

Страница 19: ...as been linked the menu expands and shows some more options 19 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm JBC 1 28174 24 W 100 JBC 1 ep mode ep temperature 150 C axim...

Страница 20: ...rature when placed on the tool holder Set Hibernation delay from 5 to 15 sec The countdown starts when the tool remains inactive no movement Select the minimum temperature that can be set for the Work...

Страница 21: ...to consult data and counts on charges Work Mode periods Sleep Mode periods errors The data can be consulted either by time periods or by number of times a certain event has occurred Documents User man...

Страница 22: ...MENU Too 28 Tool ID Hibernation dela Temperature un 00 C Tool1 Tool ID 28714 Hardware Software 0028283 X886787 Update File File Hardware Software Select your Firmware Update MENU JBC 210 Return to Wo...

Страница 23: ...sizes Choose the size that best suits your needs and the display size B115 High Precision Handle for B IRON This handle is compatible with B IRON B210 DUAL To store C115 cartridges on the tool holder...

Страница 24: ...dically check that the metal parts of the tool and tool holder are clean so that the charging works properly Maintain the tip surface clean and tinned prior to storage in order to avoid tip oxidation...

Страница 25: ...king to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the age of eight and also persons with reduced physical se...

Страница 26: ...o the product In the event of damage leakage or overheating of the batteries discontinue use immediately and contact customer support or JBC technical service facility Dispose of devices with batterie...

Страница 27: ...4 V 540 mAh Charge Time 60 minutes Selectable Temperature 100 450 C 210 840 F Idle Temp Stability still air 1 5 C 3 F Temp Accuracy 3 using reference cartridge Connections Bluetooth Low Energy BLE Am...

Страница 28: ...anty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be vali...

Отзывы: