manualshive.com logo in svg
background image

Parameter

Tool ID 

PIN  

Hibernation Delay

Sleep Mode /
Sleep Temperature

Maximum
Temperature

Tool Status

Description

Allows to change the tool identifier.

Allows to change the PIN. 

Set hibernation delay from 5 to 15 sec. The countdown starts when no 
movement is detected.

Set sleep mode ON/OFF. The tip temperature will drop to the selected 
sleep temperature while charching.

Allows selection of the maximum temperature that can be set for the work 
mode.

The tool status light indicates as follows the tool status:
- Green: working / soldering
- Green blinking: charging
- Alternating red/green blinking: low battery, less than 20%
- Red blinking: no cartridge
- No color: power OFF

Parameters

Tool

ON

MENU

28174

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

CHARGE

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

JBC

210

348ºC

5,7 W

80%

350ºC

Tool

ON

MENU

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

WORK

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

80%

JBC

210

350ºC

Tool

ON

MENU

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

CHARGE

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

JBC

210

348ºC

5,7 W

80%

350ºC

JBC#1

JBC#1

MENU

Tool1

2822

Tool ID

Hibernation delay

Temperature units

00:30

Maximum Temperature

400ºC

Sleep mode
Sleep temperature

150ºC

Working
Low battery
Power OFF

Charging
No cartridge

Tool Status

ºC

ºF

JBC

210

Lock Parameters

Locked

Unlocked

Return to Work

Tool1

Tool ID

28714

Hardware

Software

0028283

X886787

Update File

File

Hardware

Software

Select your Firmware

-
-

Update

MENU

JBC

210

Return to Work

JBC#1

Bi115

Bi210

User’s Manual

User’s Manual

Documents

MENU

JBC#1

JBC

210

Return to Work

2822

Work

Settings

Counters

Update

Documents

Light Theme

Dark Theme

Disconnect

JBC#1

OK

Update

Tool

ON

MENU

JBC#1

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

WORK

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

80%

JBC

210

350ºC

Tool1

Tool1

Tool1

Tool1

Tool2

Tool3

Tool

ON

MENU

24 W

18 W

12 W

6 W

0 W

10 seconds/div

V1.2

CHARGE

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

JBC

210

80%

350ºC

JBC#1

348ºC

6 W

10

10

Tool

ON

MENU

28174

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

CHARGE

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

JBC

210

348ºC

5,7 W

80%

350ºC

Tool

ON

MENU

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

WORK

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

80%

JBC

210

350ºC

Tool

ON

MENU

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

CHARGE

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

JBC

210

348ºC

5,7 W

80%

350ºC

JBC#1

JBC#1

MENU

Tool1

2822

Tool ID

Hibernation delay

Temperature units

00:30

Maximum Temperature

400ºC

Sleep mode
Sleep temperature

150ºC

Working
Low battery
Power OFF

Charging
No cartridge

Tool Status

ºC

ºF

JBC

210

Lock Parameters

Locked

Unlocked

Return to Work

Tool1

Tool ID

28714

Hardware

Software

0028283

X886787

Update File

File

Hardware

Software

Select your Firmware

-
-

Update

MENU

JBC

210

Return to Work

JBC#1

Bi115

Bi210

User’s Manual

User’s Manual

Documents

MENU

JBC#1

JBC

210

Return to Work

2822

Work

Settings

Counters

Update

Documents

Light Theme

Dark Theme

Disconnect

JBC#1

OK

Update

Tool

ON

MENU

JBC#1

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

WORK

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

80%

JBC

210

350ºC

Tool1

Tool1

Tool1

Tool1

Tool2

Tool3

Tool

ON

MENU

24 W

18 W

12 W

6 W

0 W

10 seconds/div

V1.2

CHARGE

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

JBC

210

80%

350ºC

JBC#1

348ºC

6 W

10

10

- Download the JBC update file from: https://www.jbctools.com/jbcsoftware.html

- Connect the console/device via USB connection to the PC.

- On the console/device notification bar at the top, open “USB Connection Settings” and select “MTP”.

- On the PC copy the downloaded file to “IT706/internal share storage/JBC”.

- Once copying is finished, disconnect the console/device from the PC.

- On the console/device open the Application (1) and then select “update” (2) on the Application Menu. 

- Use the update button of the version to be downloaded.

B·iRON Update

2

1

Update

Button

Application 

Menu

Tool

ON

MENU

28174

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

CHARGE

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

JBC

210

348ºC

5,7 W

80%

350ºC

Tool

ON

MENU

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

WORK

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

80%

JBC

210

350ºC

Tool

ON

MENU

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

CHARGE

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

JBC

210

348ºC

5,7 W

80%

350ºC

JBC#1

JBC#1

MENU

Tool1

2822

Tool ID

Hibernation delay

Temperature units

00:30

Maximum Temperature

400ºC

Sleep mode
Sleep temperature

150ºC

Working
Low battery
Power OFF

Charging
No cartridge

Tool Status

ºC

ºF

JBC

210

Lock Parameters

Locked

Unlocked

Return to Work

Tool1

Tool ID

28714

Hardware

Software

0028283

X886787

Update File

File

Hardware

Software

Select your Firmware

-
-

Update

MENU

JBC

210

Return to Work

JBC#1

Bi115

Bi210

User’s Manual

User’s Manual

Documents

MENU

JBC#1

JBC

210

Return to Work

2822

Work

Settings

Counters

Update

Documents

Light Theme

Dark Theme

Disconnect

JBC#1

OK

Update

Tool

ON

MENU

JBC#1

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

WORK

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

80%

JBC

210

350ºC

Tool1

Tool1

Tool1

Tool1

Tool2

Tool3

Tool

ON

MENU

24 W

18 W

12 W

6 W

0 W

10 seconds/div

V1.2

CHARGE

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

JBC

210

80%

350ºC

JBC#1

348ºC

6 W

10

10

tabs

new grip

Changing the Grips

Foam grips for B115 and B210 tools can be exchanged.

Remove the worn grip and replace it easily with a new one by using slip-on tabs. To change the grips 
do as follows:

1. Inserting Tabs

2. Inserting Handle

3. Removing Tabs

Menu Settings

The B·iRON Console offers an intuitive user interface, which provides quick access to station 
parameters.

Put the slide-on tabs into the 
new grip.

Hold the grip and pull the tab. 
Use pliers if necessary.

Push the grip with the tabs 
onto the handle. 

 

115

12

Содержание B iRON 115T

Страница 1: ...High Precision Battery Rework Station B iRON 115T INSTRUCTION MANUAL...

Страница 2: ...230 V United Kingdom BI115THA 230 V China BI115TJA 100 V Japan Cable USB 1 unit Ref 0028092 B iRON Console 1 unit Ref 0030035 Console not included BI115TUQA 120 V N America Taiwan BI115TIQA 230 V Indi...

Страница 3: ...sole Note For references without a console Bluetooth devices like a tablet or mobile phone can be connected Power Socket USB Connector USB Cable only for charging Stand for B115T High Precision B iRON...

Страница 4: ...tool completely 30 min before using it for the first time The status indicator light indicates as follows the tool status 2 1 Status Indicator Light 1 Connection 2 Cartridge Insertion and Charging gr...

Страница 5: ...ool1 Tool2 3 Switching on Console Device Select the tool from the detection list Turn on the console device and open the B iRON Application 4 Selecting Tool Console Work Screen Temperature and Power G...

Страница 6: ...ing and Hibernation When the tool is lifted from the stand the tip will heat up to the selected temperature When the tool is in the stand enters into Hibernation Mode and cools down to room temperatur...

Страница 7: ...and power graphics The automatic recording can be paused by tapping the screen in the graphic area The automatic recording stops also when the tool stops working While the automatic recording is stop...

Страница 8: ...moving excess solder by gently tapping or wiping the cartridge tip If the tip is very dirty JBC recommends first cleaning it with the wiper to remove excess solder and then with the brass wool Brass W...

Страница 9: ...nd that there is space for the wiper on the right Assemble the antisplash membrane in a vertical direction onto the stand Press the antisplash membrane down Make sure that the membrane is correctly in...

Страница 10: ...artridge and gently push the tweezers down Place the tweezers with the cartridge in the slot so that its reference ring rests in the slot and gently press the cartridge into the tweezers Important Pus...

Страница 11: ...ignment function Cartridge tips can be rotationally and vertically aligned Rotationally Tip Alignment Rotate the bushings slightly 1 to rotationally align the tips 2 Wheel for vertically tip aligntmen...

Страница 12: ...0 JBC 210 350 C JBC OK Tool MENU JBC 10 seconds WORK 450 C 350 C 250 C 150 C 50 C 80 JBC 210 350 C Tool MENU 10 seconds CHARGE 450 C 350 C 250 C 150 C 50 C JBC 210 80 350 C JBC 348 C 6 W 80 80 M 450 C...

Страница 13: ...0 C Tool1 Tool ID 28714 Hardware Software 0028283 X886787 MENU JBC 2 Return to Work 2822 Work Settings Counters Update Documents Light Theme Dark Theme Disconnect Update Tool ON V1 2 350 C Tool1 Tool1...

Страница 14: ...check that the metal parts of the tool and stand are clean so that the charging works properly Maintain the tip surface clean and tinned before storage in order to avoid tip oxidation Rusty and dirty...

Страница 15: ...arm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the age of eight and also persons with reduced physical sensory or mental capabili...

Страница 16: ...Notes 16...

Страница 17: ...Notes 17 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm...

Страница 18: ...Notes 18...

Страница 19: ...ctions Bluetooth Low Energy BLE Ambient Operating Temp 10 50 C 50 122 F Tool Weight 55 g 0 1 lb Console Screen dimension 7 7in With Console Total Net Weight 1462 g 3 22 lb Total Package Dimensions Wei...

Страница 20: ...anty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be vali...

Отзывы:

Похожие инструкции для B iRON 115T