2
Control Unit technical data
1. Station maximum power: 100W
2. Safety transformer with mains separator:
230V/24V 50Hz - 120V/24V 60Hz
3. Temperature range: from 100 till 400°C.
4. Programmed temperature accurate: ± 5%.
5. Green LED temperature adjustment optical
control.
6. Abides the CE standards for electrical
security, electromagnetical compatibility and
antistatic protection.
7. Equipotential connector and the tool tip are
connected to station mains ground supply for
ESD protection.
Temperature adjustment for special tips
The temperatures on the dial are set for the 75W
desoldering iron of with tip 20 DE, which is included
in the equipment. A change of tip or soldering iron
model could involve a variation of ± 7% in the set
temperature.
ENGLISH
FEATURES
Station composition
TA 5120
EU:
Ref. 5120200
TA 5120
UK:
Ref. 5120201
TA 5120
USA:
Ref. 5120100
-
Analog Control Unit 230V
Ref. 5230200
-
Analog Control Unit 120V
Ref. 5230100
-
Desoldering iron
75W
Ref. 3040000
-
Desold. iron stand UD 1500
Ref. 0290150
-
External desoldering air filter
Ref. 0781184
-
Set of tools and
replacement filters
Ref. 0781181
-
Tip removal device
Ref. 0114108
-
Instructions manual
Ref. 0965405
Weight of packaged equipment: 3,6 kg
Besides the desoldering iron supplied with this
station, the Control Unit will also take the 20W
R e f . 3 0 0 0 0 0 0 , 5 0 W R e f . 3 0 1 0 0 0 0 , 6 0 W
Ref. 3020000 with solder feed and 70W
Ref. 3070000 soldering irons.
Desoldering connector
Equipotential terminal
Spare filters
Ref.0781046
External desoldering air filter
Ref.0781184
% Vacuum indicator
and obstruction degree
in the suction circuit
Desoldering
temperature selection
The desoldering iron is connected to the station following the below procedure:
The cable connection of the desoldering iron is connected to the desoldering connector
of the station and the vacuum hose is connected to the external desoldering air filter,
which is connected to the vacuum connection of the station. Very important, it is
essential to connect the mentioned filter to prevent from damaging the vacuum pump.
Aspiration inlet
Содержание 5120100
Страница 12: ...ELECTRIC WIRING DIAGRAM RA 5150 ...
Страница 13: ...ELECTRIC WIRING DIAGRAM TA 5120 ...
Страница 14: ...RA 5150 230V ...
Страница 15: ...29 RA 5150 120V ...
Страница 16: ...TA 5120 230V ...
Страница 17: ...31 TA 5120 120V ...
Страница 18: ......