background image

WHA900

Operating Instructions

Содержание WHA5R0FE

Страница 1: ...WHA900 Operating Instructions ...

Страница 2: ...Table of Contents Page WHA900 Detail View 1 Technical Data 1 1 Cautions Warnings 2 2 Description 2 3 Placing Into Operation 2 4 Operating Guidelines 3 5 Accessories 3 6 Packing List 3 7 Nozzles 4 5 6 ...

Страница 3: ...ly 7 Fuse T 10 Amp 8 Receptacle 120 VAC Technical Data WHA900 Detailed View Dimensions 8 3 16 L 6 5 8 W 4 1 4 H Main Voltage 120 VAC Power consumption 750 WATTS Hot Air Pencil output 700 WATTS Fuse T 10 AMP Temperature Control Variable between 100 F and 1000 F Temperature Control accuracy 54 F Flow Control Variable between 5 50 l min Noise Level 56dB A distance 1m at max airflow level 1 ...

Страница 4: ...p Push Button 5 at the front of the unit The WHA900 is grounded through the 120 VAC three wire power cord Standby mode This unit has a power on function to activate a Standby Mode or secondary temperature airflow setting Before switching on the unit choose the Temperature and the Airflow settings that you would prefer to use for the Standby Mode of oper ation Activating Standby Adjust the Temperat...

Страница 5: ...rflow Knob to 4 Wait approximately 5 minutes before continuing 5 Read the temperature value indicated on the measuring instrument 6 If the temperature has to be corrected depress and hold the Start Stop push button for approximate ly 15 seconds while the hot air is activated The green LED 1 will light continuosly 7 While the green LED 1 is continuosly lit immediately turn the temperature knob slig...

Страница 6: ...s 4 Ø 1 7 x 45 mm Ø 067 x 45 in 0058736882 Ø 2 5 mm Ø 098 in 0058736881 Ø 4 mm Ø 157 in 0058736867 Ø 7 mm Ø 280 in 0058736870 Ø 2 5 x 9 5 mm Ø 098 x 374 in 0058736883 Ø 11 5 mm Ø 453 in 0058736836 RD11 Made to Order ...

Страница 7: ...83 in 0058736818 11 x 11 mm 433 x 433 in 0058736839 21 5 x 14 8 mm 846 x 583 in 0058736840 19 x 12 mm 748 x 472 in 0058736841 14 x 10 mm 551 x 394 in 0058736842 10 x 8 mm 394 x 315 in 0058736843 Measuring Nozzle 0058736875 Adapter 0058750722 ...

Страница 8: ...1 23 in 0058736833 26 x 26 mm 1 024 x 1 024 in 0058736804 20 5 x 20 5 mm 807 x 807 in 0058736807 17 5 x 23 5 mm 689 x 925 in 0058750721 18 x 18 mm 709 x 709 in 0058736814 15 5 x 13 mm 610 x 512 in 0058736837 14 x 10 mm 551 x 394 in 0058736838 ...

Страница 9: ...058736890 36 x 36 mm 1 417 x 1 417 in 0058736891 27 x 14 mm 1 063 x 551 in 0058736892 29 x 17 mm 1 142 x 669 in 0058736877 35 5 x 23 mm 1 398 x 906 in 0058736998 48 5 x 30 5 mm 1 909 x 1 201 in 0058736999 44 x 32 mm 1 732 x 1 260 in 0058736858 48 5 x 38 mm 1 909 x 1 496 in 0058750709 61 x 38 mm 2 402 x 1 496 in 0058750714 ...

Страница 10: ...Hot Air Nozzles 8 Made To Order Nozzles Contact for Quote 12 x 27 mm 472 x 1 063 in 0058736880 38 x 38 mm 1 496 x 1 496 in 0058736890 40 x 40 mm 1 575 x 1 575 in 0058736891 ...

Страница 11: ...d d T To oo ol ls s P O Box 728 Apex NC 27502 0728 U U S S S Sh hi ip pp pi in ng g A Ad dd dr re es ss s 1000 Lufkin Road Apex N C 27539 Tel 919 387 0099 Fax 919 387 2379 For inquiries concerning Technical Customer Service please call 800 476 3030 Ext 1 C Ca an na ad da a S Sh hi ip pp pi in ng g A Ad dd dr re es ss s C Co oo op pe er r T To oo ol ls s 164 Innisfil Street Barrie Ontario Canada L4...

Отзывы: