  Make sure the area below the installation place is free from unwanted persons during servicing. 

  Switch off the unit, unplug the mains cable and wait until the unit has been cooled down. 

During inspection the following points should be checked: 

  All  screws  used  for  installing  the  device  and  any  of  its  parts  should  be  tightly  fastened  and  may  not  be 

corroded. 

  Housings,  fixations  and  installations  spots  (ceiling,  truss,  suspensions)  should  be  totally  free  from  any 

deformation. 

  When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced. 

  The  mains  cables  must  be  in  impeccable  condition  and  should  be  replaced  immediately  when  even  a 

small problem is detected. 

  In order  to  protect  the  device  from  overheat the  cooling  fans  (if  any)  and  ventilation  openings  should  be 

cleaned monthly. 

  The interior of the device should be cleaned annually using a vacuum cleaner or air-jet. 

  The  cleaning  of  internal  and  external  optical  lenses  and/or  mirrors  must  be  carried  out  periodically  to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, 
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. 

  Clean with a soft cloth using normal glass cleaning products. 

  Always dry the parts carefully. 

  Clean the external optics at least once every 30 days.  

  Clean the internal optics at least every 90 days. 

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel! 
 

SPECIFICATIONS 

Mains Input: 

AC 100~240V, 50/60Hz  

Fuse: 

250V 1A slow blow (20mm glass) 

Total Power consumption:

 

30W 

Sound Control: 

Internal microphone 

DMX connections: 

3pin XLR male / female

 

 

DMX channels: 

6/9/10 channels 

DMX starting address:

 

001 

 503 

Laser Power:

 

120mW Red CW laser (

λ = 638nm) 

 

 

50mW Green CW laser (

λ = 520nm) 

 

 

300mW Blue CW laser (

λ = 450nm) 

Laser radiation class:

 

3B 

Beam diameter @ aperture:

 

<5mm 

Divergence (each beam)

 

<2 mrad 

MPE / NOHD:

 

Not relevant, the beam is continuously scattered and 

 

 

moves in all directions (no stationary laser beam)

 

Divergence (total output)

 

<90° 

Working temperature:

 

10°C to 40°C 

Laser Safety Standard:

 

EN/IEC 60825-1:2014 

Size:

 

see picture below  

Weight:

 

2.35kg 

 

 

 

Every information is subject to change without prior notice 

You can download the latest version of this user manual on our website : 

www.jb-systems.eu

 

 

Содержание B06222

Страница 1: ......

Страница 2: ......

Страница 3: ...ontrol 6 9 or 10 channels Standalone sound activated internal mic or automatic Master slave wonderful synchronized shows Built in microphone 3 digit LED display for easy menu navigation Key activated blackout switch and emergency switch interlock input for additional safety Complies to EN IEC 60825 1 2014 for Laser Safety BEFORE USE Before you start using this unit please check if there s no trans...

Страница 4: ...on t cover any ventilation openings as this may result in overheating Prevent use in dusty environments and clean the unit regularly Keep the unit away from children Inexperienced persons should not operate this device The save ambient temperature is between 15 40 C Don t use this unit at higher ambient temperatures Make sure the area below the installation place is free from unwanted persons duri...

Страница 5: ...device running unattended This laser may only be used for shows The operation of a class 3B show laser is only allowed if the operation is controlled by a skilled and well trained operator Depending on the classification operating a laser product can produce laser radiation that may cause permanent eye damage and or skin damage The legal instructions for using a laser product vary from country to ...

Страница 6: ...r immediately 6 ON OFF KEY ACTIVATED SWITCH used to switch the unit on off Use the keys to make sure only a skilled operator is able to switch the laser on 7 DMX OUTPUT 3pin female XLR connector used to connect the LASER with the next unit in the DMX chain 8 DMX INPUT 3pin male XLR connector used to connect universal DMX cables This input receives instructions from a DMX controller 9 MAINS INPUT I...

Страница 7: ...ocate the fixture in a well ventilated spot far away from any flammable materials and or liquids The fixture must be fixed at least 50cm from surrounding walls The device should be installed out of reach of people and outside areas where persons may walk by or be seated Before rigging make sure that the installation area can hold a minimum point load of 10times the device s weight Always use a cer...

Страница 8: ... FULL AUTOMATIC MODE The laser automatically runs a preprogrammed sequence Select this mode when only 1 laser is used standalone or when the laser is placed as the first master unit in a chain with several lasers Press the FUNC button until the display shows one of the following AUN S 0 9 001 or SLA Select AUN Now use the UP or DOWN buttons to select o AUN Automatic shows containing patterns and g...

Страница 9: ...F balanced cable To prevent strange behavior of the light effects due to interferences you must use a 90Ω to 120Ω terminator at the end of the chain Never use Y splitter cables this simply won t work Each effect in the chain needs to have its proper starting address so it knows which commands from the controller it has to decode DMX CONFIGURATION OF THE LASER IMPORTANT REMARK The value of CH1 is u...

Страница 10: ... blue on or strobing alternatively without red 220 255 Red green blue on or strobing alternatively CH5 Strobing 000 009 Without strobing 010 249 Strobing speed change 250 255 Strobing to sound CH6 Grating Rolling 000 Without grating revolve 000 075 Clockwise Rolling 076 150 Stop 151 255 Anticlockwise Rolling 9 CHANNEL DMX CONFIGURATION OF THE LASER CH1 between 225 and 255 Channel Value Function CH...

Страница 11: ...rating patterns CH3 Zoom 0 127 100 5 area zooming 128 169 zoom in 170 209 zoom out 210 255 zoom in zoom out CH4 Y axis Rolling 000 127 Clockwise rolling 128 255 Anticlockwise rolling CH5 X axis Rolling 000 127 Clockwise rolling 128 255 Anticlockwise rolling CH6 Z axis Rolling 000 127 0 359 degree fixed Z axis rolled 128 191 Clockwise rolling 128 255 Anticlockwise rolling CH7 X axis 000 127 128 dif...

Страница 12: ...01 075 Grating Clockwise rolling 076 150 Grating without rolling 151 255 Grating Anticlockwise rolling Pattern settings Keep the FUNC and UP button pressed simultaneously whilst connecting the laser to the mains and keep them until the display shows Press the Func button to choose the desired setting to be changed Press up or down until the laser shows the Y arrow axis on the top and X arrow axis ...

Страница 13: ...ENGLISH USER MANUAL JB SYSTEMS 11 12 SPYDER RGB LASER Pattern list ...

Страница 14: ...t Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with a soft cloth using normal glass cleaning products Always dry the parts carefully Clean the external optics at least once every 30 days Clean the internal optics at least every 90 days Attention We strongly...

Страница 15: ......

Страница 16: ......

Отзывы: