SPYDER-RGB LASER 

 

  Connect the DMX input of the laser to the DMX output of the previous unit in the chain or directly to the 

DMX-output of your controller. 

  Press the

 

FUNC-button until the dis

play shows: “001” or the actual DMX-address. 

  Press the UP/DOWN buttons to select the desired DMX-address. (001 to 503) 

  Press the ENTER-button to confirm your choice. 

  Press the FUNC-button again if you want to change the address. 

Note: 

the display blinks when the unit is in DMX-mode and no DMX-signal is detected.  

 

 
 

Some more information on DMX512:

 

The  DMX-protocol  is  a  widely  used  high  speed  signal  to  control  intelligent  light  equipment.  You  need  to 
“daisy  chain”  your  DMX  controller  and  all  the  connected  light  effects  with  a  good 
quality  XLR  M/F  balanced  cable.  To  prevent  strange  behavior  of  the  light  effects, 
due to interferences, you must us

e a 90Ω to 120Ω terminator at the end of the chain. 

Never use Y-

splitter cables, this simply won’t work!  

Each effect in the chain needs to have its proper starting address so it knows which 
commands from the controller it has to decode.  

 
DMX-CONFIGURATION OF THE LASER: 
IMPORTANT REMARK :

 The value of CH1 is used to put the laser in the desired DMX-mode. 

The SPYDER-RGB LASER has 3 DMX-modes : 6, 9 and 10 channels. 

o

 

6CH-mode : Fader CH1 between 175 and 199   

o

 

10CH-mode : Fader CH1 between 200 and 224 

o

 

9CH-mode : Fader CH1 between 225 and 255  

 

 

Channel

 

Value

 

Function

 

 

 
 

 
 

CH1

 

Mode

 

000-024

 

Laser off

 

025-049

 

Mixed show Auto.  P grating

 

050-074

 

Mixed show sound  P grating

 

075-099

 

Pattern show Auto

 

100-124

 

Pattern show sound

 

125-149

 

Grating show Auto

 

150-174

 

Grating show sound

 

175-199

 

Grating dot show DMX

 

200-224

 

Grating pattern show DMX

 

225-255

 

Original pattern show DMX

 

Содержание B06222

Страница 1: ......

Страница 2: ......

Страница 3: ...ontrol 6 9 or 10 channels Standalone sound activated internal mic or automatic Master slave wonderful synchronized shows Built in microphone 3 digit LED display for easy menu navigation Key activated blackout switch and emergency switch interlock input for additional safety Complies to EN IEC 60825 1 2014 for Laser Safety BEFORE USE Before you start using this unit please check if there s no trans...

Страница 4: ...on t cover any ventilation openings as this may result in overheating Prevent use in dusty environments and clean the unit regularly Keep the unit away from children Inexperienced persons should not operate this device The save ambient temperature is between 15 40 C Don t use this unit at higher ambient temperatures Make sure the area below the installation place is free from unwanted persons duri...

Страница 5: ...device running unattended This laser may only be used for shows The operation of a class 3B show laser is only allowed if the operation is controlled by a skilled and well trained operator Depending on the classification operating a laser product can produce laser radiation that may cause permanent eye damage and or skin damage The legal instructions for using a laser product vary from country to ...

Страница 6: ...r immediately 6 ON OFF KEY ACTIVATED SWITCH used to switch the unit on off Use the keys to make sure only a skilled operator is able to switch the laser on 7 DMX OUTPUT 3pin female XLR connector used to connect the LASER with the next unit in the DMX chain 8 DMX INPUT 3pin male XLR connector used to connect universal DMX cables This input receives instructions from a DMX controller 9 MAINS INPUT I...

Страница 7: ...ocate the fixture in a well ventilated spot far away from any flammable materials and or liquids The fixture must be fixed at least 50cm from surrounding walls The device should be installed out of reach of people and outside areas where persons may walk by or be seated Before rigging make sure that the installation area can hold a minimum point load of 10times the device s weight Always use a cer...

Страница 8: ... FULL AUTOMATIC MODE The laser automatically runs a preprogrammed sequence Select this mode when only 1 laser is used standalone or when the laser is placed as the first master unit in a chain with several lasers Press the FUNC button until the display shows one of the following AUN S 0 9 001 or SLA Select AUN Now use the UP or DOWN buttons to select o AUN Automatic shows containing patterns and g...

Страница 9: ...F balanced cable To prevent strange behavior of the light effects due to interferences you must use a 90Ω to 120Ω terminator at the end of the chain Never use Y splitter cables this simply won t work Each effect in the chain needs to have its proper starting address so it knows which commands from the controller it has to decode DMX CONFIGURATION OF THE LASER IMPORTANT REMARK The value of CH1 is u...

Страница 10: ... blue on or strobing alternatively without red 220 255 Red green blue on or strobing alternatively CH5 Strobing 000 009 Without strobing 010 249 Strobing speed change 250 255 Strobing to sound CH6 Grating Rolling 000 Without grating revolve 000 075 Clockwise Rolling 076 150 Stop 151 255 Anticlockwise Rolling 9 CHANNEL DMX CONFIGURATION OF THE LASER CH1 between 225 and 255 Channel Value Function CH...

Страница 11: ...rating patterns CH3 Zoom 0 127 100 5 area zooming 128 169 zoom in 170 209 zoom out 210 255 zoom in zoom out CH4 Y axis Rolling 000 127 Clockwise rolling 128 255 Anticlockwise rolling CH5 X axis Rolling 000 127 Clockwise rolling 128 255 Anticlockwise rolling CH6 Z axis Rolling 000 127 0 359 degree fixed Z axis rolled 128 191 Clockwise rolling 128 255 Anticlockwise rolling CH7 X axis 000 127 128 dif...

Страница 12: ...01 075 Grating Clockwise rolling 076 150 Grating without rolling 151 255 Grating Anticlockwise rolling Pattern settings Keep the FUNC and UP button pressed simultaneously whilst connecting the laser to the mains and keep them until the display shows Press the Func button to choose the desired setting to be changed Press up or down until the laser shows the Y arrow axis on the top and X arrow axis ...

Страница 13: ...ENGLISH USER MANUAL JB SYSTEMS 11 12 SPYDER RGB LASER Pattern list ...

Страница 14: ...t Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with a soft cloth using normal glass cleaning products Always dry the parts carefully Clean the external optics at least once every 30 days Clean the internal optics at least every 90 days Attention We strongly...

Страница 15: ......

Страница 16: ......

Отзывы: