background image

ENGLISH 

 

USER MANUAL

 

 
JB SYSTEMS® 

5/12 

SPYDER-RGB LASER 

 

13.  DISPLAY:

 shows the selected DMX address when the unit is in DMX-mode. Apart from DMX-mode you 

can also select 4 other working modes, see further to learn more about these modes. 

14.  INTERNAL MICROPHONE: 

The built-in microphone is used to synchronize the laser show to the beat of 

the music. 

 

IMPORTANT! For your own safety we strongly recommend to connect this optional switch! 

THERE WILL BE NO LASER OUTPUT WHEN THE INTERLOCK INPUT IS NOT USED! 

Temporary solution: install the spare connector on the laser. (see picture) 

 

 

OVERHEAD RIGGING 

 

Important:

 

The  installation  must  be  carried  out  by  qualified  service  personal  only.  Improper 

installation  can  result  in  serious  injuries  and/or  damage  to  property.    Overhead  rigging  requires 
extensive  experience!  Working  load  limits  should  be  respected,  certified  installation  materials 
should be used, the installed device should be inspected regularly for safety.

 

  Make sure the area below  the installation place  is free from unwanted persons  during rigging, de-rigging 

and servicing. 

  Locate  the  fixture  in  a  well  ventilated  spot,  far  away  from  any  flammable  materials  and/or  liquids.  The 

fixture must be fixed 

at least 50cm

 from surrounding walls. 

  The device should be installed out of reach of people and outside areas where persons may walk by or be 

seated. 

  Before rigging make sure that the installation area can hold a minimum poi

nt load of 10times the device’s 

weight. 

  Always use a certified safety cable that can hold 12 times the weight of the device when installing the unit. 

This  secondary  safety  attachment  should  be  installed  in  a  way  that  no  part  of  the  installation  can  drop 
more than 20cm if the main attachment fails. 

  The device should be well fixed; a free-swinging mounting is dangerous and may not be considered! 

 

Don’t cover any ventilation openings as this may result in overheating.  

  The operator has to make sure that the safety-relating and machine-technical installations are approved by 

an expert before using them for the first time. The installations should be inspected every year by a skilled 
person to be sure that safety is still optimal. 

 
HOW TO SET UP AND CONTROL THE UNIT 

 

 

 
MUSIC INPUT SENSITIVITY:

  

The unit works to rhythm of the beat when used in standalone or master/slave mode

 

To set the input sensitivity, follow these steps: 

 

Содержание B06222

Страница 1: ......

Страница 2: ......

Страница 3: ...ontrol 6 9 or 10 channels Standalone sound activated internal mic or automatic Master slave wonderful synchronized shows Built in microphone 3 digit LED display for easy menu navigation Key activated blackout switch and emergency switch interlock input for additional safety Complies to EN IEC 60825 1 2014 for Laser Safety BEFORE USE Before you start using this unit please check if there s no trans...

Страница 4: ...on t cover any ventilation openings as this may result in overheating Prevent use in dusty environments and clean the unit regularly Keep the unit away from children Inexperienced persons should not operate this device The save ambient temperature is between 15 40 C Don t use this unit at higher ambient temperatures Make sure the area below the installation place is free from unwanted persons duri...

Страница 5: ...device running unattended This laser may only be used for shows The operation of a class 3B show laser is only allowed if the operation is controlled by a skilled and well trained operator Depending on the classification operating a laser product can produce laser radiation that may cause permanent eye damage and or skin damage The legal instructions for using a laser product vary from country to ...

Страница 6: ...r immediately 6 ON OFF KEY ACTIVATED SWITCH used to switch the unit on off Use the keys to make sure only a skilled operator is able to switch the laser on 7 DMX OUTPUT 3pin female XLR connector used to connect the LASER with the next unit in the DMX chain 8 DMX INPUT 3pin male XLR connector used to connect universal DMX cables This input receives instructions from a DMX controller 9 MAINS INPUT I...

Страница 7: ...ocate the fixture in a well ventilated spot far away from any flammable materials and or liquids The fixture must be fixed at least 50cm from surrounding walls The device should be installed out of reach of people and outside areas where persons may walk by or be seated Before rigging make sure that the installation area can hold a minimum point load of 10times the device s weight Always use a cer...

Страница 8: ... FULL AUTOMATIC MODE The laser automatically runs a preprogrammed sequence Select this mode when only 1 laser is used standalone or when the laser is placed as the first master unit in a chain with several lasers Press the FUNC button until the display shows one of the following AUN S 0 9 001 or SLA Select AUN Now use the UP or DOWN buttons to select o AUN Automatic shows containing patterns and g...

Страница 9: ...F balanced cable To prevent strange behavior of the light effects due to interferences you must use a 90Ω to 120Ω terminator at the end of the chain Never use Y splitter cables this simply won t work Each effect in the chain needs to have its proper starting address so it knows which commands from the controller it has to decode DMX CONFIGURATION OF THE LASER IMPORTANT REMARK The value of CH1 is u...

Страница 10: ... blue on or strobing alternatively without red 220 255 Red green blue on or strobing alternatively CH5 Strobing 000 009 Without strobing 010 249 Strobing speed change 250 255 Strobing to sound CH6 Grating Rolling 000 Without grating revolve 000 075 Clockwise Rolling 076 150 Stop 151 255 Anticlockwise Rolling 9 CHANNEL DMX CONFIGURATION OF THE LASER CH1 between 225 and 255 Channel Value Function CH...

Страница 11: ...rating patterns CH3 Zoom 0 127 100 5 area zooming 128 169 zoom in 170 209 zoom out 210 255 zoom in zoom out CH4 Y axis Rolling 000 127 Clockwise rolling 128 255 Anticlockwise rolling CH5 X axis Rolling 000 127 Clockwise rolling 128 255 Anticlockwise rolling CH6 Z axis Rolling 000 127 0 359 degree fixed Z axis rolled 128 191 Clockwise rolling 128 255 Anticlockwise rolling CH7 X axis 000 127 128 dif...

Страница 12: ...01 075 Grating Clockwise rolling 076 150 Grating without rolling 151 255 Grating Anticlockwise rolling Pattern settings Keep the FUNC and UP button pressed simultaneously whilst connecting the laser to the mains and keep them until the display shows Press the Func button to choose the desired setting to be changed Press up or down until the laser shows the Y arrow axis on the top and X arrow axis ...

Страница 13: ...ENGLISH USER MANUAL JB SYSTEMS 11 12 SPYDER RGB LASER Pattern list ...

Страница 14: ...t Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with a soft cloth using normal glass cleaning products Always dry the parts carefully Clean the external optics at least once every 30 days Clean the internal optics at least every 90 days Attention We strongly...

Страница 15: ......

Страница 16: ......

Отзывы: