5.6 STANDALONE operation

In standalone operation, up to 20 program steps can be stored in the P18 Wash, which can then 
run in an endless loop. The images can be saved in two ways. Either you program the desired 
DMX values directly on P18 Wash and save them, or you set the DMX values via a connected 
DMX console and then store them in the P18 Wash.
The menu items MODIFY, RUN and REMOTE can only be called up using a specific key 
combination. To do this, press and hold “ENTER”, and also press “ESC”. Before activating these 
menu items, remove all other devices in the DMX line that send DMX, e.g. consoles or other 
spotlights that are not configured as slave devices, as otherwise damage to the DMX drivers 
may occur.

Programming the standalone programme on the spotlight display:

Call up the STANDALONE, EDIT menu item. In the STEP NR+/- menu item, select the desired step 
and you can change it and its channel parameters in the following menu items: In the MODIFY 
menu item, set the desired lighting scene and position and determine the individual sequence 
times of the steps with FADE TIME and NEXT TIME (time for the complete step).
Use INSERT to insert an additional programming step. The DMX values of the previous step are 
copied to the new step.
Use DELETE to delete a step. The display shows STEP NR: 1/X. Use the selection keys to move 
to the desired step.
With RESET STEP you reset one step to its default values (DMX 000). The display shows STEP 
NR: 1/X. Use the selection keys to select your step. CLEAR ALL resets the complete standalone 
programming steps. Under MODIFY you will find STEP1/1 again. In the STANDALONE, TIMEBASE 
menu item you have the possibility to change the Fade Time and Next Time from 1 second to 
1/10 second.

Launch the standalone program:

Call up the STANDALONE menu and navigate to the RUN submenu. Confirm the selection by 
pressing the key combination “ENTER” (press and hold) and simultaneously “ESC”. The display 
then shows: S-ALONE: 01/XX and the program runs in an endless loop. 
Deactivation: Press and hold the “ESC” key and then also press "ENTER". The menu jumps back 
one level and RUN appears in the display.

Operation via master-slave function:

Connect the P18 Wash via DMX lines and activate the REMOTE menu item for all slave devices. 
To do this, navigate in the STANDALONE menu to the REMOTE sub-menu. Activate the REMOTE 
function by pressing and holding “ENTER”, and also pressing “ESC”. The spotlight is in slave 
mode when the display shows the status REMOTE INACTIVE or REMOTE ACTIVE. 
REMOTE INACTIVE: The P18 Wash is in slave mode but does not receive a DMX signal. 
REMOTE ACTIVE: The P18 Wash is in slave mode and receives a DMX signal.
The master device is programmed via the MODIFY menu item and started via RUN (press 
and hold “ENTER” and also press “ESC”).

Accept the DMX values from an external console:

To accept the DMX values of a connected console, you must first enable the Capture DMX input. 
To do this, go to the CAPT DMX menu item. The display now shows CAPTURE DMX 01/01, press 
the Enter key to switch to START CAPTURE. Now the P18 Wash reacts to the signals from the 
external console.

From Spotlight Software 1.5 the standalone operation can also be programmed via the App 
we offer.

Содержание P18 Wash

Страница 1: ...Operating instructions Version 1 02 Software 1 00 P1 8 Wash ...

Страница 2: ... 02 P1 8 Wash ...

Страница 3: ...view 14 5 2 FACTORY DEFAULTS Factory settings 16 5 3 USER DEFAULTS User settings 16 5 4 DMX NET ADDRESS DMX addressing Artnet addressing 16 5 5 PERSONALITY Personal settings 16 5 6 STANDALONE operation 18 5 7 INFO 19 5 8 Shortcuts quick access 19 6 Channel assignment 20 6 1 Operating modes 20 6 2 DMX channel assignment Mode 1 and Mode 2 22 6 3 Control channel 25 6 4 Zoom auto focus distance autofo...

Страница 4: ...läche Abmess Lichtanlagentechnik GmbH Sallersteig 15 89134 Blaustein 630 435 480 5 140 140 258 4 307 267 541 Name Erstellt Art Nr Datum Prisma Fax 07304 9617 99 Tel 07304 9617 0 P18 komplett_Hülle 17 01 2018 Kuehngruen Allgemeintoleranzen ISO 2768 m Blechdicke Material Farbe Oberfläche Abmessung Lichtanlagentechnik GmbH Sallersteig 15 89134 Blaustein 435 480 5 140 140 258 4 307 6 754 Name Erstellt...

Страница 5: ... 0 P18 17 01 2018 Kuehngruen Allgemeintoleranzen ISO 2768 m Blechdicke Material Farbe Oberfläche Abmessung Lichtanlagentechnik GmbH Sallersteig 15 89134 Blaustein Head Fresnel front lens Tilt lock Arm PowerCON TRUE1 Output Pan lock DMX Ethernet USB ports Base PowerCON TRUE1 Input Bottom cover Top cover Arm cover Handles LCD display Function keys ...

Страница 6: ...re replacing fuses or parts The mains plug must always be accessible after the spotlight has been installed Do not overload the sockets or extension cables as this could result in fire or electric shock Do not place any objects on the power cable Do not install the spotlight in such a way that people can trip over or step on the power cable Make sure that the power cable can never be crushed or da...

Страница 7: ... not exposed to extreme heat moisture or dust Ventilation openings and slots in the head and foot of the spotlight are used for ventilation to ensure reliable operation of the device and to protect it from overheating these openings must not be covered Never cover the front lens when the spotlight is in use The openings should never be covered with substances or other objects so that the airways a...

Страница 8: ...esifthedeviceistobetransported When using the original packaging the locks must not be closed ATTENTION Only have plugs installed by a specialist The P18 Wash spotlight is supplied with a partially assembled power cable with the powerCON TRUE1 plug only the powerCON TRUE1 plug is included in the US version The installation of the safety plug or the connection of the P18 Wash to the power supply 10...

Страница 9: ... acti vated or a DMX signal is present Connection outside Europe The P18 Wash may only be operated on the following power supply systems Mains P18 Wash 2 wires 1 phase L N L N PE 3 wires 1 phase L N L L N 4 wires 3 phases L1 L2 L3 N L N PE ATTENTION In Canada the P18 Wash may only be operated in a 2 wire 1 phase network with a maximum voltage of 120V The P18 Wash has a powerCON TRUE1 out power out...

Страница 10: ...ts are 5 pin XLR connectors which can be purchased in specialist shops Pin assignment Pin1 Ground Shielding Pin2 DMX Pin3 DMX Pin4 Data out Pin5 Data out 1 2 3 4 5 1 2 3 4 5 Cable with shielding 4 4 1 DMX cabling 4 4 2 Ethernet cabling Ethernet cabling can be done with standard network lines The sockets on the device are Neutrik etherCON sockets Special cables with etherCON connectors are recommen...

Страница 11: ...in the base must not be covered with anything 140 258 4 140 Erstellt D Fax 0 Tel 0 06 Allgem IS Lichtanla Sallersteig 1 2 4 3 To mount the unit on a trussing system use two of the original JB Lighting omega brackets with original Camloc connectors You have following four possibilities to mount the omega brackets The Camlocs must snap in to be locked properly Ensure that the structure truss to whic...

Страница 12: ...a menu item UP and DOWN are used to navigate within the menu and to enter values Special areas can only be called up using a specific key combination To do this press and hold the ENTER key and then use the opposite ESC key to access the menu To exit the function proceed in reverse order This applies in the SERVICE area for the FINE ADJUST function and in the STANDALONE area for the MODIFY RUN and...

Страница 13: ...tion shows an error in the ERROR LIST is still in it but has already been confirmed or was automatically confirmed Only when the error has been deleted from the ERROR LIST does the P18 Wash start again without error signalling If errors occur again and again contact the dealer distributor or our service department If the P18 Wash receives a DMX signal the display illumination goes out after 30 sec...

Страница 14: ...UNT 1 CLEAR SURE DMX TEST DMX CHANNEL CH 001 DISPLAY CONTR D CONTR 000 UP USER DEFAULTS LOAD DEFAULTS SURE SAVE DEFAULTS SURE PASSWORD COOLING MODE STANDARD BOOST SHORTEST DIST ON OFF CAMERA MODE 60 HZ FLEX 50 HZ LINEAR LONGLIFE FINE ADJUST OFS FOCUS RECEIVE SOFTW SURE THEATRE WHISPER THEATRE SILENT FAST DMX ADDRESS ADDRESS ARTNET ADDRESS DMX MODE MODE 1 MODE 2 ON OFF DEFAULT IP NETWORK 10 NETWORK...

Страница 15: ...US FOCUS ZOOM ZOOM IRIS IRIS BL 1A BL 1B BL 2A BL 2B BL 3A BL 3B BL 4A BL 4B BL 1A BL 1B BL 2A BL 2B BL 3A BL 3B BL 4A BL 4B COLOR 1 CYAN MAGENTA BL ROT BL ROT COLOR 1 CYAN EFF MAGENTA TEMP HEAD DRV ACTUAL MAX RESET YELLOW CTO SPARKLE SPARKLE SP FROST FROST 2 SPEED P T SPEED EFF MOVE B OUT YELLOW CTO SPARKLE SPARKLE SP FROST FROST 2 SPEED P T SPEED EFF MOVE B OUT TEMP BASE PS ACTUAL MAX RESET TEMP...

Страница 16: ... connection button must be pressed briefly on the transmitter The transmitter is now looking for all fixtures where wireless is enabled and fixtures that are not connected to a transmitter If the P18 Wash has successfully connected to the transmitter the display shows a level indication of the current reception quality If the P18 Wash is additionally connected via the DMX etherCON connection socke...

Страница 17: ...er slightly downwards and thus remains at the same volume up to 60 C STANDARD Brightness 32000lm all effect pan tilt speeds run at full speed From an ambient temperature of approx 36 C the fans run to cool the LED accordingly The brightness remains constant up to 60 ambient temperature BOOST Brightness 34000lm all effect pan tilt speeds run at full speed The fans run a little stronger in this mode...

Страница 18: ...EAR ALL resets the complete standalone programming steps Under MODIFY you will find STEP1 1 again In the STANDALONE TIMEBASE menu item you have the possibility to change the Fade Time and Next Time from 1 second to 1 10 second Launch the standalone program Call up the STANDALONE menu and navigate to the RUN submenu Confirm the selection by pressing the key combination ENTER press and hold and simu...

Страница 19: ... be deleted The following temperatures are also displayed TEMP BASE LCD the temperature on the display board TEMP BASE PS the temperature of the power supply unit TEMP HEAD MAIN the temperature of the head board TEMP HEAD DRV the temperature of the LED driver board TEMP HEAD LED the temperature of the LED module TEMP HEAD AMBIENT the temperature in the head next to the air inlet ambient temperatur...

Страница 20: ...rture 2b Fine iris Channel 17 Aperture 3a Aperture 1a Channel 18 Aperture 3b Aperture 1a fine Channel 19 Aperture 4a Aperture 1b Channel 20 Aperture 4b Aperture 1b fine Channel 21 Aperture rotation Aperture 2a Channel 22 Colour wheel 1 Aperture 2a fine Channel 23 Colour wheel 2 Aperture 2b Channel 24 Cyan Aperture 2b fine Channel 25 Magenta Aperture 3a Channel 26 Yellow Aperture 3a fine Channel 27...

Страница 21: ... 21 P1 8 Wash Channel 44 CTO fine Channel 45 Sparkle Channel 46 Sparkle speed Channel 47 Frost 1 Channel 48 Frost 2 Channel 49 Pan tilt speed Channel 50 Effect speed Channel 51 Blackout Move ...

Страница 22: ...ra Mode 60Hz after 2 sec Camera Mode FLEX after 2 sec Camera Mode High FLEX after 2 sec Safety Reset after 2 sec Safety 000 007 032 039 064 071 096 103 128 135 160 160 161 161 162 162 163 163 164 164 208 215 216 223 224 227 228 231 232 239 240 247 248 255 6 6 Shutter Shutter closed Shutter open Open pulsing shutter 20Hz rapid slow Shutter open Fade effect with dimmer slow rapid Shutter open Shutte...

Страница 23: ... 1a fine 16 Bit 000 255 14 19 Aperture 1b 0 100 000 255 20 Aperture 1b fine 16 Bit 000 255 15 21 Aperture 2a 0 100 000 255 22 Aperture 2a fine 16 Bit 000 255 16 23 Aperture 2b 0 100 000 255 24 Aperture 2b fine 16 Bit 000 255 17 25 Aperture 3a 0 100 000 255 26 Aperture 3a fine 16 Bit 000 255 18 27 Aperture 3b 0 100 000 255 28 Aperture 3b fine 16 Bit 000 255 19 29 Aperture 4a 0 100 000 255 30 Apertu...

Страница 24: ... 192 223 224 255 23 36 Color wheel 2 Open 2700K 3200K 4200K 7000K 9000K 12000K Dark blue 000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 255 24 37 Cyan 8 Bit 0 100 000 255 38 Fine cyan 16 Bit 000 255 25 39 Magenta 8 Bit 0 100 000 255 40 Fine magenta 16 Bit 000 255 26 41 Yellow 8 Bit 0 100 000 255 42 Fine yellow 16 Bit 000 255 27 43 CTO 8 Bit 0 100 000 255 44 Fine CTO 16 Bit 000 255 28 ...

Страница 25: ...ming out and DMX 007 for slow dimming out This range is repeated five times and thus the P18 Wash is adapted to the reaction time speed of the light controllers DMX 000 007 for rapid light controllers and DMX 128 135 for slow light controllers In the range from DMX 160 to DMX 164 the Cooling and Volume operating modes can be set To do this the dimmer and shutter of the spotlight must be closed and...

Страница 26: ... the spotlight DISPLAY CONTRAST The contrast of the LCD display may change when the temperature is too high In this menu item the contrast can be adjusted RECEIVESOFT This area can be used to import the software of the P18 Wash see page 27 Animation effects can be created via this channel in connection with the focus Depending on the intensity the projection can be made to shake more or less This ...

Страница 27: ...nnect the flap replace the Phillips screws 4 and return the inserts to the unit 4 5 2 1 3 7 5 Software update The P18 Wash can be updated via a USB stick with micro USB connection To do this copy the file directly into the root directory of the USB stick Then press and hold the right key below the display Now insert the P18 Wash as soon as the message Insert USB stick appears on the display and re...

Страница 28: ...ce White light LED module 1000W Luminous intensity 34000 Lumen 20 C Luminous intensity HCRI 27000 Lumen 20 C Effects Pan 561 0 Tilt 281 0 Zoom 13 65 Construction Colour black Housing PC ABS Protection class IP 20 Plug in technology yes Installation Installation site indoors Holder 2x Omega brackets Position any Minimum distance to flammable objects 0 5 m Connections Power input Neutrik powerCON TR...

Страница 29: ...uring methods Limit value class A Radiation Information technology equipment radio interference characteristics EN 55022 2010 Limit values and measuring methods Limit value class A Harmonic currents Electromagnetic compatibility EN 61000 3 2 2015 Part 3 2 Limits testing of harmonic currents for devices with an input current 16A per phase Flicker Electromagnetic compatibility EMC EN 61000 3 3 2013 ...

Страница 30: ... 30 P1 8 Wash ...

Страница 31: ... 31 P1 8 Wash ...

Страница 32: ...JB Lighting Lichtanlagentechnik GmbH Sallersteig 15 89134 Blaustein Tel 49 7304 9617 0 Fax 49 7304 9617 99 info jb lighting de www jb lighting de ...

Отзывы: