- 13 -
NOTE
: “L” means left
hand installation
,
“R” means right
hand installation (viewed inside
looking out)
13.7 Lock door setting (Optional function)
Press and hold
“SET” button for 3 seconds until the LED flashes “1”.
Press “UP” or “DOWN” button to increase or decrease. Adjust the
LED
to flash “6”, press “SET” button to enter into lock door setting. The LED
displays the current setting.
Press “UP” button, the LED displays “1”, the lock door function is on. Press “DOWN” button, the LED
displays”0”, the lock door function is off. Press “SET” button to confirm, the opener returns to standby
mode.
When the lock door function is on and the door is fully closed, the opener will lock the door
automatically. And then the door can only be opened by a transmitter after being unlocked by the
“lock” key(S2) on the transmitter. (If
the opener is not unlocked by the S2 button on the transmitter,
the light will flash twice when pressing the open key on the transmitter)
The default setting is: Off
13.8 Half-open setting (Optional function)
Press and hold
“SET” button for 3 seconds until the LED flashes “1”.
Press “UP” or “DOWN” button to increase or decrease. Adjust the LED to
flash “7”. Press “SET” button to enter into half
-open setting. The LED
displays the current setting.
Press “UP” or “DOWN”
button to increase or decrease. When the LED di
splays ”1”, the half
-open
height is 30cm. When the LED displays “2”, the half
-
open height is 60cm. When the LED displays “3”,
the half-
open height is 90cm. When the LED displays “0”, the half
-open function is
off. Press “SET”
button to confirm, the opener returns to standby mode.
If the half-open function is on, only when the door is fully closed, the door can be half-opened by the
“S1” key on the transmitter. If the door is at
an
other position, the “S1” key w
ill not work.
The default setting is : Off
13.9 9. Alarm and maintenance function
When the LED flashes and the display shows "A", this means the opener working cycles have been
exceeded. Call Technician for service.