Gb
Fr
- 78 -
324501E
revision02
De
See appendix
B
for connection of the power supply according to
receiver version.
Caution:
The electrical connections should be made such that when
the main switch is off, the OR remote control receiver is also
deactivated.
Do not apply any lever movement to the screwdriver as this can result in damaging
the terminal strip and the printed circuit on the motherboard of the receiver ORR.
To open the ORRS and ORRA connection terminal strips:
- Vertically insert the screwdriver (flat tip screwdriver of
1.5 to 3 mm width) in the slot located opposite the wire,
- Insert the wire,
- Remove the screwdriver.
6.7- Wiring recommendations
Generalities :
Do not place cables of different classes side by side.
A minimum space (20 cm) should be observed between the different classes:
- Class 1 :
Radio, antenna cable (case of an antenna extension)
- Class 2 :
Mains for power supply of various units
- Class 3 :
Power control for motors, variable speed drive, etc....
Ideally, each cable class should be run through a cable path specific to the class. If
only one cable path is available, cables of different classes should be separated as
much as possible.
6.7.2- Wiring the power supply of receiver ORR
6.7.1- Wiring the receiver ORR
If flexible stranded wire is used, crimped terminations should be used to avoid false
contacts and short circuits.
)
)
)
)
)
To avoid any risks of electrocution, do not open the receiver
housing when receiver is power supplied.
WARNING
Содержание ORION Series
Страница 2: ...2 324501E revision02...
Страница 123: ...Gb De 324501E revision02 123 Fr Annexes Appendix Anhang...
Страница 134: ...134 324501E revision02...
Страница 136: ...136 324501E revision02...
Страница 137: ...324501E revision02 137 NOTES...
Страница 138: ...138 324501E revision02 NOTES...
Страница 139: ...324501E revision02 139...