6.2- Choice of operating radio frequency
To ensure good operating quality, it is important that the radio channel used be free
throughout the area in which the machine will be controlled.
If several radio remote controls are operating on the same site, frequencies spaced
by at least
two radio channels
(for example: 5, 7, 9 ...) should be used and, if
necessary, a frequency plan should be drawn up, specifying the various machines
controlled and their working frequency.
6.3- «Continuous NC or NO» relay operating mode
If a system is used in continuous mode with the control buttons maintained pressed
and the operator moving about, transmission interruptions can occur due to the
dispersion and propagation of radiowaves which must be taken into account in
accordance with the application.
6.5- «Multifunction» transmitters equipped with
accumulators and charger support (ORCL•) :
When transmitters are equipped with accumulators, please charge them for
approximately 3 hours before a first use.
6.4- Minimum and maximum current of relay outputs
Be sure not to exceed the minimum and maximum characteristics specified in §
2.3.3 by installing, if necessary, an additional load or intermediate relays (auxiliary
contacts in electrical cabinet for power control, for example).
Содержание ORION Series
Страница 2: ...2 324501E revision02...
Страница 123: ...Gb De 324501E revision02 123 Fr Annexes Appendix Anhang...
Страница 134: ...134 324501E revision02...
Страница 136: ...136 324501E revision02...
Страница 137: ...324501E revision02 137 NOTES...
Страница 138: ...138 324501E revision02 NOTES...
Страница 139: ...324501E revision02 139...