Configuration
TriPad Configuration
How to Work with DELTAD-G2/G2D
47
www.javad.com
Values are 0 to [231
-1
]. The default value is 0 (zero). Zero means that an unlimited number of log
files will be created.
• Files (remain) - specifies the number of files left for the receiver to create in AFRM.
• Values are 0 to [231
-1
]. The default value is zero.
• Automatically remove old files - when no free memory is available to log data,
automatically removes the earliest log file. If this parameter is enabled, your receiver will
erase the file with the earliest file creation time/date. AFRM must be enabled to use this
FIFO (First-In, First-Out) feature.
• The default value is off (disabled).
Data Recording Auto-start parameter
These radio buttons allow you to program your receiver's behavior in the event of a power failure.
Table below gives the different scenarios available and the results after power is restored to the
receiver. “Specified file” refers to the file name entered in the Always append to file parameter.
Also, if Always is enabled, your receiver will automatically start logging data (to a newly created or
an existing file) in the following three cases:
• After pressing the Power button to turn on the receiver.
• After resetting the receiver (with TriVU).
• After taking the receiver out of Sleep Mode.
Before Power Failure
Enabled Radio Button Results
Off
On
Always
1
Receiver data logged to
file specified.
Data logging will not
resume when power is
restored.
Receiver will resume
data logging to the
same file when power
is restored.
Receiver will resume data
logging to the
same file when power is
restored.
2
Receiver data logged
to default file.
Data logging will not
resume when power is
restored.
A new log file will
open when power is
restored and data will
log to this file.
A new log file will open when
power is restored and data will
log to this file.
3
File specified; receiver
data logging not started.
No file will open with
this name.
Data logging will not
start when power is
restored.
No file will open with
this name.
Data logging will not
start when power is
restored.
A log file with this name will
open and data logging will start
after power is restored.
4
No file specified;
receiver data logging off.
Data logging will not
start when power is
restored.
Data logging will not
start when power is
restored.
A log file with a default name
will open and data logging will
start after power is restored.