7
6
2.0 SPECIFICATIONS
EN
REF
FEATURES
TECHNICAL SPECIFICATIONS
2.1
Refrigerants
EPA Certified to ARI 740-98 for refrigerants, HFC,HCFC and CFC
2.2
Safety
Designed to meet UL1963, AS standards & EU equivalents
2.3
Power
220/240 VAC/50Hz, 110-115 VAC/50Hz
2.4
Compressor
3/4 HP oil less, BLDC motor drive
2.5
Cooling
Fan direct
2.6
Protection
High pressure switch cutoff at 3850 Kpa
Compressor protected by brushless DC drive circuit
2.7
Pressure
Max low side design pressure 2600Kpa
Max high side design pressure 3800Kpa
2.8
Temperature
Operating range 10°C to 40°C
2.9
Case
Injection moulded glass reinforced high impact
2.10
Size
L 320mm X W 220mm X H 260mm
2.11
Weight
8.5 Kg
REFRIGERANT
LIQUID RATE
(Kg/Min) (Kg/Hr)
VAPOUR RATE
(Kg/Min) (Kg/Hr)
PUSH/PULL
RATE
(Kg/Min) (Kg/Hr)
RESIDUAL
TRAPPED
REFRIGERANT
(Kg)
R22
2.30/138
0.31/18.6
7.10/426
<0.1
R134-a
2.00/120
0.25/15
5.80/348
<0.1
R410A
1.65/99
0.30/18
7.00/420
<0.1
XTRULTRA-2 A5 safety-operation-manual.indd 6
01/02/2018 15:42