background image

*ASON)NTERNATIONAL)NCs

 

501.771.4477  

 

 

 

Page 5 of 12

 

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2013 Jason International.

INSTALLATION INSTRUCTIONS (cont.)

FIELD INSTALLATION OF THE MICROSILK

®

 PUMP 

ASSEMBLY

The Jason MicroSilk

®

 system has been factory assem-

bled following ETL and IAPMO guidelines. For shipping 

 

purposes, on some bath models, the MicroSilk

®

 Pump As-

sembly may be packaged separately and disconnected from 
the bath.

NOTE: These instructions can also be found in the 
Installation, Operation and Maintenance manual of the 
separately packaged MicroSilk

®

 therapy bath unit.

WARNING:  SYSTEM UNDER PRESSURE – NEVER PER-
FORM MAINTENANCE WHILE SYSTEM IS RUNNING.

Note: Verify the MicroSilk

®

 Pump Assembly is the same unit 

that was provided for the bath being installed. The serial 
number listed on the label provided on the MicroSilk

®

 Pump 

Assembly carton should match the serial number of the bath.

Warning: Any modification to the equipment is not 
recommended and will VOID the manufacturer’s 

 

warranty.

To install the MicroSilk

®

 Pump Assembly to the bath, the 

following procedures must be followed.

Note: Do not install the MicroSilk

®

 Pump Assembly further 

than the length of the tubing that is factory installed on the 
bath. These tubing lengths have been designed for proper 
drainage of the system.

1.  Position the bath in the area of intended installation.

2.  Before beginning any work, the installer is to determine 

the proper location of the MicroSilk

®

 Pump Assembly 

and service access.

3.  Do not disconnect the plumbing lines that are secured 

to the bath with nylon tie straps (Figure 5).

Figure 4

Figure 5

4.  Clamp the MicroSilk

®

 Jet Line to the MicroSilk

®

  

Discharge Barb using the clamp provided on the 

 

tubing. Assure the MicroSilk

®

 Jet Line will allow proper 

drainage to the Jets (Figure 6). The discharge hose 
must have a continuous drop from the discharge barb 
to the jet fitting.

5.  Clamp the MicroSilk

®

 Suction Line to the MicroSilk

®

 Suc-

tion Barb using the clamp provided on the tubing. Assure 
the MicroSilk

®

 Suction Line will allow proper drainage 

to the suction (Figure 7). The suction hose must have 
a continuous drop from the suction barb to the suction 
fitting.

Figure  6

Figure  7

Содержание Integrity

Страница 1: ...onsible for ensuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been avoi...

Страница 2: ...ylic surface of this bath has been provided with a protective film which helps protect the bath during shipment and installation Additional protection may also be required to protect the acrylic surfa...

Страница 3: ...ACTUATOR FULL SUPPORT BASE PUMP MOUNT FULL SUPPORT BASE Dedicated 120V 60 Hz GFCI Protected Service L2 L1 GROUND DEDICATED 240V 50 or 60 Hz GFCI PROTECTED SERVICE NOTE USE THE ABOVE DIAGRAM FOR 240V...

Страница 4: ...ipment or other heat producing components of the unit 4 Whirlpool Equipment This Whirlpool bath is provided with an Air On Off switch The pump is pre wired to a control box which has a 36 cord Connect...

Страница 5: ...warranty To install the MicroSilk Pump Assembly to the bath the following procedures must be followed Note Do not install the MicroSilk Pump Assembly further than the length of the tubing that is fac...

Страница 6: ...isconnect the blower from the air bath plumbing by removing the two 2 screws on the check valve outlet and disconnect the short piece of flex pipe between the check valve and the elbow by removing the...

Страница 7: ...start the MicroSilk unit Press the Air On Off button again to stop the MicroSilk unit MicroSilk Unit The MicroSilk unit generates oxygen rich microbubbles that fill the bath MicroSilk units provided...

Страница 8: ...th unit and its plumbing are designed to drain after each use whether used as a hydrotherapy bath soaking bath or just taking a shower Air ON OFF Button TheAirOn Offbuttonprovidesasafe andconvenientme...

Страница 9: ...on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment ALL WARRANTY REPAIRS MUST BE AUTHORIZED...

Страница 10: ...re plug is fully inserted into the outlet c Air Switch is disconnected or defective c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and t...

Страница 11: ...k System usu ally surges b Make sure union is tight on suction side of the purmp Pump does not manually shutoff a Defective keypad or control a Refer to installer dealer Replace keypad or control Pump...

Страница 12: ...EXPRESSED OR IMPLIED AS TO ANY MATTER WHATSOEVER INCLUDING THE CONDITION OF THE MERCHANDISE ITS MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ANY WARRANTIES IMPLIED BY LAW AND NOT EF FECTIVELY...