background image

*ASON)NTERNATIONAL)NCs

 

501.771.4477  

 

 

 

Page 11 of 12

 

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2013 Jason International.

TROUBLE SHOOTING GUIDE (cont’d)

WHIRLPOOL PUMP SYSTEM

SYMPTOMS

POSSIBLE CAUSES

RECOMMENDED ACTION

Pump system won’t start.

a)  No power to the pump unit.

a)  Reset circuit breakers and check GFCI.  Check fuses 

and replace if bad.

b)  Pump motor is not plugged in.

b)  Make sure plug is fully inserted into the ourlet.

c)  Air Switch is disconnected or 

defective.

c)  Check and reconnect if necessary.

Pump operates, but no air is 
injected into water.

a)  Air line is clogged.

a)  Refer to installer/dealer.

Pump operates, but water is not 
being pumped.

a)  Suction or discharge blocked.

a)  Remove obstruction.

b)  Suction air leak.  (System usu-

ally surges.)

b)  Make sure union is tight on suction side of the purmp.

Pump does not manually shutoff.

a)  Defective keypad or control

a)  Refer to installer/dealer.  Replace keypad or control.

Pump unions leak.

a)  Unions cracked, under-tight-

ened, over-tightened, or O-ring 
is not seated properly (possi-
bly pinched).

a)  Refer to installer/dealer.  Replace keypad or control.

Pump shuts off by itself.

a)  Pump motor overheated and 

thermal protection device 
deactivated motor. (Possibly 
low voltage.)

a)  Make sure motor air cooling vents are not  blocked.  

Clear and allow motor to cool down. (Check service & 
wire size.)

b)  GFCI tripped.

b)  Refer to installer /dealer.

c)  Water fell below recommended 

level.

c)  Fill to recommended level (2” [50 mm] above jets).

LED light will not operate.

a)  LED light is loose in socket.

a)  Access LED light and assure it is properly installed in 

socket.

b)  LED cable disconnected.

b)  Verify correct cabel connections.

Содержание Integrity

Страница 1: ...onsible for ensuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been avoi...

Страница 2: ...ylic surface of this bath has been provided with a protective film which helps protect the bath during shipment and installation Additional protection may also be required to protect the acrylic surfa...

Страница 3: ...ACTUATOR FULL SUPPORT BASE PUMP MOUNT FULL SUPPORT BASE Dedicated 120V 60 Hz GFCI Protected Service L2 L1 GROUND DEDICATED 240V 50 or 60 Hz GFCI PROTECTED SERVICE NOTE USE THE ABOVE DIAGRAM FOR 240V...

Страница 4: ...ipment or other heat producing components of the unit 4 Whirlpool Equipment This Whirlpool bath is provided with an Air On Off switch The pump is pre wired to a control box which has a 36 cord Connect...

Страница 5: ...warranty To install the MicroSilk Pump Assembly to the bath the following procedures must be followed Note Do not install the MicroSilk Pump Assembly further than the length of the tubing that is fac...

Страница 6: ...isconnect the blower from the air bath plumbing by removing the two 2 screws on the check valve outlet and disconnect the short piece of flex pipe between the check valve and the elbow by removing the...

Страница 7: ...start the MicroSilk unit Press the Air On Off button again to stop the MicroSilk unit MicroSilk Unit The MicroSilk unit generates oxygen rich microbubbles that fill the bath MicroSilk units provided...

Страница 8: ...th unit and its plumbing are designed to drain after each use whether used as a hydrotherapy bath soaking bath or just taking a shower Air ON OFF Button TheAirOn Offbuttonprovidesasafe andconvenientme...

Страница 9: ...on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment ALL WARRANTY REPAIRS MUST BE AUTHORIZED...

Страница 10: ...re plug is fully inserted into the outlet c Air Switch is disconnected or defective c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and t...

Страница 11: ...k System usu ally surges b Make sure union is tight on suction side of the purmp Pump does not manually shutoff a Defective keypad or control a Refer to installer dealer Replace keypad or control Pump...

Страница 12: ...EXPRESSED OR IMPLIED AS TO ANY MATTER WHATSOEVER INCLUDING THE CONDITION OF THE MERCHANDISE ITS MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ANY WARRANTIES IMPLIED BY LAW AND NOT EF FECTIVELY...

Страница 13: ...onstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a phys...

Отзывы: