background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 1 of 12

 

 

 

 

Customer Service :  800.255.5766 

“TO BE REMOVED FOR USE BY THE OCCUPANT.”

INSPECTION

Inspection of the unit prior to installation is the responsibility 

of the installer. All components are factory assembled to the 

bath and the unit is water tested and inspected prior to leaving 

Jason International, Inc. If the carton shows sign of damage, 

inspect the product before accepting and describe the problem 

on the Bill of Lading.   

Note: 

 Transportation and insurance 

from Jason’s factory are the buyer’s responsibility.

Damage sustained in transit is the responsibility of the carrier. If 

damage is discovered, the carrier must be immediately notified 

in writing with a request for a representative to inspect the 

unit. Failure of the carrier to respond should be reported to 

the seller and carrier. Always file a freight claim promptly.

The installer is responsible for insuring that the unit is free 

from defects or shipping damage. In the event of a problem, 

DO NOT install the unit. Jason International is not responsible 

for damage that might have been avoided by inspection or 

testing prior to installation.

Damage to the unit during installation will not be covered 

by  warranty  and  is  the  responsibility  of  the  installer.  ALL 

WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE 

MUST  BE  MADE  PRIOR  TO  INSTALLATION.  Inspect 

OwNer’s MaNual

forma™ air-whirlpool Baths

INsTallaTION, OPeraTION, aND MaINTeNaNCe

49-1000-016

Date   04/08

Table 1 - Specifications

Jason International, Inc.

 

8328 MacArthur Drive

North Little Rock, AR 72118

www.jasoninternational.com

OwNer’s reCOrD

Dealer: 

Date Purchased: 

Date Installed: 

Installer: 

PlaCe serIal NuMBer CarD wITh 

PrODuCT CONfIguraTION IN ThIs BOx

CAUTION: DO NOT LIFT OR HANDLE THE BATH BY ITS PLUMBING.

plumbing  and  bath  surface  for  missing  or  damaged 

components. Alert your dealer of any discrepancies.

To protect the unit from damage keep the bath in the carton 

until ready for installation.

Model

Overall

Dimension

L x W x H (in.)

Operating

Capacity

gal

Blower

120v /

240v hP

Pump

120v /

240v hP

Min. Size

access

w x h 

(in.)

floor

Loading

lbs/ft

2

AIR-WHIRLPOOL

AC630

72 x 36 x 22

45

1

1.5

36 x 17

56.7 lbs

AC635

72 x 42 x 22

56

1

1.5

36 x 17

52.9 lbs

CN550

60 x 60 x 22

66

1

1.5

36 x 17

51.9 lbs

DA500

60 x 60 x 20.5

55

1

1.5

36 x 17

49.5 lbs

RC630

72 x 36 x 22

50

1

1.5

36 x 17

52.5 lbs

RC635

72 x 42 x 22

58

1

1.5

36 x 17

52.9 lbs

RE525

60 x 30 x 20.5

38

1

1.5

36 x 17

61.6 lbs

RE527

60 x 32 x 20.5

39

1

1.5

36 x 17

59.5 lbs

RE553 

66 x 36 x 22

47

1

1.5

36 x 17

55.2 lbs

RE630

72 x 36 x 22

53

1

1.5

36 x 17

54.1 lbs

Содержание forma Series

Страница 1: ...by warranty and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION Inspect Owner s Manual forma Air Whirlpool Baths INSTALLATION OP...

Страница 2: ...lower and pump mount s to rest firmly on the floor The bottom of the blower and pump mount s must be secured and level with the bottom of the bath We recommend securing the blower and pump mounts to t...

Страница 3: ...ons are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the unions hand tight then loosen the unions s and check the O ring sea...

Страница 4: ...r GFCI In the unlikely occurrence of a current imbalance in the power conductors the GFCI will interrupt the power to the bath GROUNDING IS REQUIRED Theunitshouldbeinstalledbyaqualifiedservicerepresen...

Страница 5: ...he same time everyday See Operating the Signature Edition Air Whirlpool Touchpad on pages 8 9 REMOTE CONTROL FEATURES In addition to the main control touchpad installed on the bath deck a floating wat...

Страница 6: ...box must be plugged into a 120v 15 amp GFCI dedicated circuit H Pre wired power cord to the blower I Air whirlpool control box connections SIGNATURE EDITION AIR WHIRLPOOL PARTS LIST Pump Pump Control...

Страница 7: ...jets Blowers provided on Jason Air Whirlpool baths are factory tested when assembled and again retested after installation on the Air Whirlpool bath STANDARD EDITION AUTOMATIC PURGE Fifteen minutes af...

Страница 8: ...mandMedium to High The system remembers the last speed setting on the next startup The Blower Speeds icon will light up when the blower is running The LED displays the blower speed from 10 Low or 55 M...

Страница 9: ...again to increase the blower speed until the desired intensity is reached The blower will return to its highest speed on any mode change Option The Option icon is used to operate an optional LED ligh...

Страница 10: ...commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acrylic paste wax Buff the surface with a clean soft cloth Do not use s...

Страница 11: ...le was disabled a Remove power to the bath either by the circuit breaker or by unplugging and replugging the blower from the supply outlet PumpSystem of Air Whirlpool Bath Symptoms Possible Causes Rec...

Страница 12: ...tors hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a...