background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 10 of 12

 

 

 

 

Customer Service :  800.255.5766 

HUMIDITY

Warning: Avoid high humidity levels in your home. Mold, mildew, 

fungi and bacteria which may be harmful to health thrive in areas with 

continued high humidity levels; therefore, every precaution should 

be taken to make sure your plumbing fixtures including bathtubs, 

therapy baths, or showers do not become a source of high humidity 

due to improper installations or leaks.

To avoid having your plumbing fixtures become a source of 

unwanted humidity, please make sure the following steps are 

taken prior to installation.

1. Make sure the area where the bathtub or shower is installed is 

well vented and allows enough ventilation and air circulation 

to dry the bathroom environment within a short time after 

taking a bath or shower.

2. If your bath or shower unit is tiled-in, use units with an 

integral tile flange or make sure a tile flange kit or a similar 

mechanical barrier is installed to prevent shower spray, 

splash, or overflow to leak behind the bathtub.

3. Make sure the plumber properly tests your therapy bath 

before it is roughed in to make sure there are no leaks and 

it is installed with proper access to bath equipment.

4. Make sure that all the plumbing and fixtures in the bathroom 

are in good working order and have no leaks.

5. Do not use carpeting or other materials or furniture, which 

can hold moisture in your bathroom.

6. Use disinfectant to clean any bathroom surfaces which are 

regularly exposed to moisture.

7.  Clean  and  disinfect  humidifier  and  dehumidifiers  as 

recommended by the manufacturer. replace the air filter 

on the HVAC unit once a month.

8. Clean moldy surfaces as soon as any mold appears by using 

a  detergent/soapy  solution  and  appropriate  household 

cleaner. Always use gloves during cleaning. Dispose of 

any sponges or rags used to clean mold.

CLEANING

With minimum care, your acrylic-surfaced bath will retain its 

high-luster finish for many years. For regular cleaning use 

Jason Bath Cleaner or a mild NONABRASIVE liquid detergent 

solution (i.e. glass cleaner) and a soft, wet cloth or sponge. 

Do not run the air system with foaming cleaners or soaps. 

Rinse the bath thoroughly after cleaning.

SURFACE MAINTENANCE

Areas with minor scratches or dull surfaces can be restored 

by applying commercially available plastic polish (i.e. Novus 

Plastic Polish No. 2, available at your Jason dealer), followed 

by an application of acrylic paste wax. Buff the surface with 

a  clean  soft  cloth.  Do  not  use  sandpaper,  steel  wool,  or 

abrasive rubbing compounds. 

If scratches are too deep to rub out, or if the damage penetrates 

the acrylic surface, consult your dealer for recommendations 

on surface repair.

AIR HEATER AND AIR TEMPERATURE

The air heater incorporated into the air blower is designed 

to preheat the incoming air to body temperature, not to heat 

the bath water. The air heater automatically comes on when 

the air blower is activated. 

Even  though  all  Air-Whirlpool  baths  provide  preheated 

air,  occasionally  some  people  with  sensitive  skin  might 

experience a cold air sensation. This sensation is caused 

by the swiftly moving heated air bubbles blowing on the wet 

skin. This phenomenon can be related to the use of a fan for 

cooling on a hot day. While the ambient temperature does 

not change, the moving air makes you feel cooler. Avoiding 

this cold air sensation is among the reasons Jason avoids 

placing air jets directly beneath the body. If you experience 

a cool air sensation, which is most noticeable during the first 

few minutes of an Air-Whirlpool bath, simply move your body 

slightly away from the closest jets.

FLUSHING / SANITIZING

Upon start-up and not to exceed 90 days, your Air-Whirlpool bath and 

plumbing system should be flushed. 

Follow the Sani-Design™ 

Cleaning instructions provided with the bath.

REPAIR

refer all plumbing or electrical repair to a qualified service 

technician.  dO  nOT  ATTEMpT  TO  rESOLVE  THE 

PROBLEM.  This  can  result  in  danger  of  electrical  shock 

or  damage  to  the  unit  and  will  VOId  THE  WArrAnTY. 

Remember,  when  contacting  your  dealer  or  service 

representative,  always  have  your  serial  number,  proof  of 

purchase, and model number. This will insure a quick response 

on warranty items. The serial number can be found on the 

front page of this manual or on the small card adhered to 

the back of the bath just above the blower.

Jason International, Inc. (Jason), warrants its baths to be free from defects in workmanship and materials as provided in the enclosed Warranty 

statement and Warranty validation card.

The pre-addressed warranty registration card MUST be filled out by the purchaser within thirty (30) days from purchase and mailed to Jason 

International, Inc., in order for the limited warranty to become effective.

warraNTY

USER MAINTENANCE INSTRUCTIONS

Содержание forma Series

Страница 1: ...by warranty and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION Inspect Owner s Manual forma Air Whirlpool Baths INSTALLATION OP...

Страница 2: ...lower and pump mount s to rest firmly on the floor The bottom of the blower and pump mount s must be secured and level with the bottom of the bath We recommend securing the blower and pump mounts to t...

Страница 3: ...ons are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the unions hand tight then loosen the unions s and check the O ring sea...

Страница 4: ...r GFCI In the unlikely occurrence of a current imbalance in the power conductors the GFCI will interrupt the power to the bath GROUNDING IS REQUIRED Theunitshouldbeinstalledbyaqualifiedservicerepresen...

Страница 5: ...he same time everyday See Operating the Signature Edition Air Whirlpool Touchpad on pages 8 9 REMOTE CONTROL FEATURES In addition to the main control touchpad installed on the bath deck a floating wat...

Страница 6: ...box must be plugged into a 120v 15 amp GFCI dedicated circuit H Pre wired power cord to the blower I Air whirlpool control box connections SIGNATURE EDITION AIR WHIRLPOOL PARTS LIST Pump Pump Control...

Страница 7: ...jets Blowers provided on Jason Air Whirlpool baths are factory tested when assembled and again retested after installation on the Air Whirlpool bath STANDARD EDITION AUTOMATIC PURGE Fifteen minutes af...

Страница 8: ...mandMedium to High The system remembers the last speed setting on the next startup The Blower Speeds icon will light up when the blower is running The LED displays the blower speed from 10 Low or 55 M...

Страница 9: ...again to increase the blower speed until the desired intensity is reached The blower will return to its highest speed on any mode change Option The Option icon is used to operate an optional LED ligh...

Страница 10: ...commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acrylic paste wax Buff the surface with a clean soft cloth Do not use s...

Страница 11: ...le was disabled a Remove power to the bath either by the circuit breaker or by unplugging and replugging the blower from the supply outlet PumpSystem of Air Whirlpool Bath Symptoms Possible Causes Rec...

Страница 12: ...tors hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a...

Отзывы: