FEATURES, CONTROLS AND OPERATING INSTRUCTIONS (cont.)
SIGNATURE EDITION ELECTRONIC CONTROLS
ICONS
AIRMASSEUR Icon
MICROSILK Icon
LED Icon (Premier & Signature)
Blower SPEED Icon
SIGNATURE EDITION OPERATING INSTRUCTIONS
The Signature Edition digital touchpad mounted on the bath features an LCD readout which alternately indicates the water
temperature (+/-5°F) and time remaining. The control keypad features several icons used by the bather to control the
bath. This section will outline the functions of the system when a particular icon is pressed.
Unless otherwise indicated an ON/OFF function will take place with a single press on the button icon. Some functions may
require the use of a long press. A built-in timer shuts off the therapy equipment twenty (20) minutes after being activated.
Customized Settings
The 12-character LCD display can be customized by pressing the AIRMASSEUR® and SPEED icons simultaneously for
five (5) seconds while the system is off. Note: These icons will not be illuminated during this process. Use the SIGNA-
TURE EDITION ELECTRONIC CONTROLS chart to locate the icons. A menu will be displayed to choose the following:
Purge 24 (starts the blower every 24 hours for two (2) minutes at the time the purge was set), Product Test Diagnostics,
Temperature (°F or °C) and Language (English or Spanish).
Menu Instructions
Use the top AIRMASSEUR® icon to scroll through the different menu items. Use the Blower SPEED icon to change an
option. For example, press and release the AIRMASSEUR icon to change from Product Test to the Temperature option.
Press and release the SPEED icon to change the temperature display from Fahrenheit (°F) to Celsius (°C).
Product Test Diagnostics
After selecting the Product Test option from the menu, the unit will perform a series of tests to confirm correct installation
of components. The test will begin by displaying the configuration number, followed by the software revision number.
Next, the auxiliary control box will be tested to ensure proper IR communication. The display will then test the Tempera-
ture and Low Water level sensor (ITW-209). Next, each of the six (6) icon buttons will begin to light. Press the illuminated
button to proceed to the next icon. After the icon test, the equipment will start for two (2) seconds. Lastly, the LED light
units will be tested. If you receive an error on any of the tests, confirm proper installation of components to the correct
control box. (See CONTROL BOX CONNECTIONS section)
MicroSilk
®
[MS]
AirMasseur
®
[AM]