A WILKINSON STAR LIMITED PRODUCT 12-16 ISSUE 1
Unpacking
Check the packaging for any signs of damage. Carefully remove the machine and retain the packaging
until the installation is complete.
Location
The machine should be located in a suitable position and environment. Care should be taken to avoid
moisture, dust, steam, oil or corrosive gases
Place on a secure level surface and ensure that there is adequate clearance around the machine to
ensure natural airflow.
Input connection
Before connecting the machine you should ensure that the correct supply is available. Details of the
machine requirements can be found on the data plate of the machine or in the technical parameters
shown in the manual.
The equipment should be connected by a suitably qualified competent person. Always ensure the
equipment has a proper grounding. Never connect the machine to the mains supply with the panels
removed.
Output connections
Electrode polarity
In general when using manual arc welding electrodes the electrode holder is connected the positive
terminal and the work return to the negative terminal. Always consult the electrode manufacturer’s data
sheet if you have any doubts.
When using the machine for TIG welding the TIG torch should be connected to the negative terminal and
the work return to the positive terminal.
MMA welding
Insert the cable plug with electrode holder into the “+” socket on the front panel of the welding machine,
and tighten it clockwise. Insert the cable plug of the work return lead into the “-”ve socket on the front
panel of the welding machine, and tighten it clockwise