Page 35
Lift TIG: 5 "Welding Mode" when in Welding Engineer Mode .
1) If the "Welding Mode" is MIG, set the MIG
post-flow time, with range 0-5.0, accuracy of 0.5, and
unit of seconds.
2) If the "Welding Mode" is Lift TIG, set the Lift TIG
post-flow time, with range 0-10.0, accuracy of 0.5,
and unit of seconds.
Lift TIG
downslope
time
F05
0.5
Set the Lift TIG downslope time, with range 0-5,
accuracy of 0.5, and unit of seconds.
Burn back
voltage
F06
13
Set the MIG burn back voltage, with range 10-20,
accuracy of 0.1, and unit of voltages.
Hot start
current
F07
30
Set the MMA hot start current, with range 0-60,
accuracy of 1, and unit of amperes.
Slow wire
feed speed
F08
1
Set the slow wire feed speed of MIG; can be set to
"0", "1", "2" or "3".
1) "0" indicates that the slow wire feed function is
disabled.
2) "1", "2" or "3" indicate that the slow wire feed
speed is 1/3, 1/2 or 2/3 of the current set speed,
respectively.
Remote
control mode
F09
0
Can be set to "0" or "1" to use wireless or wired
remote controller.
1) "0" indicates wireless remote controller.
2) "1" indicates wired remote controller.
Note!
If entering the Welding Engineering Mode from different "Welding Mode" states,
the functional definition corresponding to the background parameters/functions may
be also different! For example: If entering the Welding Engineering Mode background
from the MIG welding mode, the pre-flow/post-flow time set are the pre-flow/post-flow
time of MIG mode.
Note! Some models do not support F09. Please confirm with the seller whether the
machine supports this function before purchasing.
Содержание MIG160PFC
Страница 5: ......
Страница 59: ...Page 59 Appendix 2 List of common spare parts List of common spare parts 1 MIG160 MIG200...
Страница 61: ...Page 61 List of common spare parts 2 MIG160PFC MIG200PFC...
Страница 63: ...Page 63 List of common spare parts 3 MIG250...
Страница 66: ...Page 66 List of common spare parts 4 MIG250PFC...
Страница 70: ...Page 70...