Page 32
6.1.4 Welding engineer mode function
The Welding Engineer Mode function allows users to set/modify the default parameters
/functions as follows:
1) Press and hold "Parameter Adjustment Knob A" for 5s in startup state.
2) After pressing and holding the "Parameter Adjustment Knob" for 2s, the machine will count
down from 3s; at the end of the countdown, "Parameter Display A" on the display window will
display a parameter number, such as "F01". "Parameter Display B" on the display window will
display the value corresponding to that number.
3) Rotate "Parameter Adjustment Knob A" to select the parameter number to set the
back-end parameter/function.
4) Rotate "Parameter Adjustment Knob B" to set the value corresponding to that parameter
number.
5) Press "Parameter Adjustment Knob A" to save the new value.
6) After setting the value, press "Welding Method Selection" key to exit the Welding Engineer
Mode.
7) Refer to the following table for the parameter numbers, function definitions and
configuration values
Background
parameter
/function
Parameter
No.
Default
value
Function definition
Standby
response time
F01
10
Can be set to four values: "0", "5", "10" or "15".
1) "0" indicates that the standby function is disabled
and the machine will not enter standby state.
2) "5", "10" and "15" indicate that the standby function
is enabled and the machine will enter the standby state
after the corresponding time (unit: minutes).
Input
overvoltage
/undervoltage
protection
F02
0
Can be set to "0" or "1".
1) "0" indicates that the overvoltage/undervoltage
protection function is disabled.
2) "1" indicates that the overvoltage/undervoltage
protection function is enabled.
Note: The standard version only supports
overvoltage protection function.
Pre-flow time
F03
MIG: 0.1
Lift TIG:
0.5
Set the MIG/Lift TIG welding parameters based on the
"Welding Mode" when in Welding Engineer Mode.
1
)
If the "Welding Mode" is MIG, set the MIG pre-flow
time, with range of 0-2.0, accuracy of 0.1, and unit of
seconds.
If the "Welding Mode" is Lift TIG, set the Lift TIG
pre-flow time, with range of 0-5.0, accuracy of 0.5, and
unit of seconds.
Post-flow time
F04
MIG: 0.5
Lift TIG:
Set the MIG/TIG welding parameters according to the
"Welding Mode" when in Welding Engineer Mode.