Page 19
the other end to the gas regulator outlet, and secure it with a clamp.
5.3.2 DCEN
1) Ensure that the welder power switch is turned off.
2) Insert the torch plug into the central socket on the front panel of the welder and tighten it
clockwise.
3) Insert the cable plug with earth clamp into the positive polarity socket on the front panel of
the welder and tighten it clockwise.
4) Insert the polarity changeover connector into the negative polarity socket on the front panel
of the welder and tighten it clockwise.
5) Connect one end of the gas hose to the gas valve inlet on the rear panel of the welder, and
the other end to the gas regulator outlet, and secure it with a clamp.
NOTE! When performing carbon steel flux-cored self-shielded welding, please replace
with dedicated knurling wire feed roller and use "DCEN".
When performing aluminum magnesium alloy welding, please replace with U-groove
wire feed roller, contact tip, and 2.0 mm diameter Teflon liner for aluminum welding,
and use "DCEP".