36
OPERATION
-
MIG
Before starting any welding activity ensure that you have suitable eye protection and
protective clothing. Also take the necessary steps to protect any persons within the welding
area.
MIG/MAG Synergic Welding Mode
Synergic Welding Control:
The top control dial and display area (P)
when synergic mode is selected amperage
control becomes the default adjustment
setting on this display (as shown left).
The combined rotary encoder and push
button which when pressed will scroll the
operator through amperage control, wire feed speed and material thickness as shown below:
Amperage control
-
(welding voltage range will vary depending on material and wire size selected)
Wire Feed Speed control
-
(Wire feed speed will vary depending on material/wire size selected)
Material thickness setting
-
(material thickness range will vary depending on material/wire size
selected)
For example, when rotating the encoder in synergic mode gives the operator the ability to adjust welding
current and rotating the control dial clockwise increases not only the welding current but also the
background wire feed speed and material thickness settings.
While rotating the control dial anticlockwise will decrease the wire feed speed ultimately reducing
welding current.
Synergic Welding Control:
The bottom control dial and display area
(Q) when synergic mode is selected
welding voltage is the default adjustment
setting on this display (as shown right).
The combined rotary encoder and push
button which when pressed will scroll the
operator through welding voltage, arc length, inductance and burn back as shown below:
Voltage, Inductance and Burn Back Controls
Welding Voltage (welding voltage adjustment range is 11 ~ 26V)
Arc Length Voltage (noted by the
‘
V
’
icon flashing, arc length voltage range is –
5 ~ +5
volts)
Inductance (Inductance adjustment range is –
10 ~ +10)
Burn Back Time (Burnback time adjustment range is 0 ~ 800ms)
To access welding voltage, arc length voltage, inductance and burn back time, simply press the lower
control dial (Q) which will scroll you through these 4 options. Please refer to page 25 for further