73
TROUBLESHOOTING
-
ERROR CODES
The following operation requires sufficient professional knowledge on electric aspects and
comprehensive safety knowledge. Make sure the input cable of the machine is disconnected
from the electricity supply and wait for 5 minutes before removing any machine covers.
The control display is also used for providing error messages to the user, if an error message is displayed,
the power source may only function to a limited capacity and the cause of the error should be checked
as soon as possible.
The below is a list of error codes for the Jasic EVO EM
-
160 and EM
-
200 welding machines.
Error
Code
Error Code
Description
Possible Cause
Check
E10
Overcurrent
protection
The output is at
maximum capacity
current of machine
Turn the machine off and back on again.
If overcurrent protection alarm is still active, contact
your suppliers approved technician.
E31
Undervoltage
protection
The input mains
voltage is too low
Turn the machine off and back on again.
If the alarm continues, check the input voltage.
If the input voltage is within specification and the
alarm persists, contact your suppliers approved
technician.
E32
Overvoltage
protection
The input mains
voltage is too high
Turn the machine off and back on again.
If the alarm continues, check the input voltage.
If the input voltage is within specification and the
alarm persists, contact your suppliers approved
technician.
E34
Undervoltage
protection
Under voltage in
inverter circuit
Turn the machine off and back on again.
If the alarm continues, check the input voltage.
If the input voltage is within specification and the
alarm persists, contact your suppliers approved
technician.
E60
Overheating
An over temperature
signal received from
the output rectifier
circuit
Do not turn off the machine, wait for a while and
after the thermal error goes off then you can
continue welding.
While error code is ON, machine cannot cut.
Ensure cooling fans are operational.
Decrease duty cycle welding activity.
E61
Overheating
An over temperature
signal received from
the Inverter IGBT
circuit
Do not turn off the machine, wait for a while and
after the thermal error goes off then you can
continue welding.
While error code is ON, machine cannot cut.
Ensure cooling fans are operational.
Decrease duty cycle welding activity.
Abnormal VRD
VRD voltage is too
high or too low
Turn the machine off and back on again.
If the fault VRD alarm persists, contact your suppliers
approved technician.