15
TECHNICAL DATA / SCOPE OF DELIVERY / ELECTRICAL CONNECTION
Technical data & scope of delivery
electrical connection
Technical data
Power supply
230 V AC
Switching capacity (max�)
< 400 W
Radio frequency
433,05-433,92 MHz
Standby consumption
≤ 1 W
Protection class
IP 20
Permissible temperature range
0°C b is + 50 °C
Duty cycle Relay output
ca. 240 Sek.
Radio channels
1 Kanal
Compatibility
Jarolift TDRC hand and wall transmitter
Scope of delivery
After unpacking, compare the con-
tents of the package with the informa-
tion on the scope of delivery in these
instructions:
1. Radio receiver TDRR02W
(Power supply unit / receiver
module)
2. Support frame
3. Outer frame
4. Operating instructions
1
2
3
4
There is a danger to life from electric shock when working on electrical equipment!
• The mains connection of the radio receiver and all work on electrical installations may only be carried out by
an authorised electrician in accordance with the connection diagrams in this manual. by an authorised electri-
cian in accordance with the connection diagrams in this manual.
• Carry out all installation and connection work in a de-energised state.
Mains connection
(L1)
Phase
N
Neutral conductor
Motor connection
N
Neutral conductor blau
Up (Down)
brown (black)*
Down (UP)
black (brown)*
PE Protective conductor green-yellow
* depending on the mounting position of the
motor