background image

DS1124     Revised: 10-Sep-2018

1102 Rupcich Drive

Millennium Park

Crown Point, IN 46307

TEL: (219) 663-1600 FAX: (219) 663-4562

e-mail: [email protected]

www.janusfiresystems.com

The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and 

fitness for a particular purpose, except as expressly stated in the seller’s sales contract or sales acknowledgment form. Every 

attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can 

all requirements be anticipated. All specifications are subject to change without notice.

Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company.

Ordering Information

Model Number  Description 

P/N

MOM-4

Monitored Output Module

99239

N/A

EOL Resistor/Diode Assembly for Releasing Circuit

18712

SMD10-3A

Sync Module

18710

Page 4 of 4

Содержание MOM-4

Страница 1: ...When the output is activated the LED will turn on constantly In case of trouble the LED will turn off Since the system allows maximum 13 LEDs on devices to turn on constantly if system already has 13 lighted LEDs on devices MOM 4 will not turn on the LED and keep flashing even if the output of MOM 4 is activated P N 99239 24 VDC Monitored Output Control 5 1k ohm EOL NAC or Releasing Control LED in...

Страница 2: ...of each other and be enclosed within conduit or equivalently protected against mechanical injury When NACs are connected to MOM 4 module each MOM 4 module shall be separated by short circuit isolators SCI to avoid influence from a short circuit of the SLC Signal Line Circuit Wiring Diagram Setting the Address Figure 2 Output Connected to a Notification Appliance Circuit Page 2 of 4 SLC loop wiring...

Страница 3: ... 4 module The Manual Release Function immediately activates the Suppression System in the same zone It overrides Delay Time and Abort Functions for that zone Figure 3 Output Connected to a Releasing Device Before connecting an output device connect the module to the SLC loop and reset it with the FACP This is necessary to ensure that the internal relay is unlatched Connection of the module with th...

Страница 4: ...ated in the seller s sales contract or sales acknowledgment form Every attempt is made to keep our product information up to date and accurate All specific applications cannot be covered nor can all requirements be anticipated All specifications are subject to change without notice Note Approvals Listings maintained by and manufactured by Potter Electric Signal Company Ordering Information Model N...

Отзывы: