background image

REX F-1-9 and REX F-3-9 – Standalone or Access Controller 

 

 

 

 

3/2015 

Black line 

www.jantar.si 

Function 4) Pre-alarm and alarm  

Set the pre-alarm time. This is the time in which the controller, with short 
beeps, alerts you that the door was left open. If you don’t close the door in 
the pre-alarm time, the alarm will be triggered and signaled with long beeps 
by the controller. The time can be set in seconds or minutes. Switching time 
from seconds to minutes and back, can be adjusted by using the function 15. 

Set the pre-alarm time with master fingerprint:

 

 

Place the master fingerprint four times on the sensor and remove it (4 
double beeps). The controller will start to beep every second. Each beep 
indicates 1 second or 1 minute of the pre-alarm time. Duration of the pre-

alarm time can

 

be max 120 seconds or 60 minutes. When you hear the 

required number of beeps, place a user fingerprint on the sensor

 

or approach 

a user card for confirmation. 

 

Set the pre-alarm time with master card:

 

 

Approach the master card and remove it after 4 double beeps. The controller 
will start to beep every second. Each beep indicates 1 second or 1 minute of 
the pre-alarm time. Duration of the pre-alarm time can

 

be max. 120 seconds 

or 60 minutes. When you hear the required number of beeps, approach a 
user card

 

or place a user fingerprint on the sensor for confirmation. 

 

Function 5) Negate / Switch output state

 

This function is used, when you connect an electric strike or electric magnet 
which needs power supply to remain in locked state. 

Switch output state with master fingerprint:  

Place the master fingerprint five times on the sensor and remove it (5 double 
beeps). Within a period of three seconds place a user fingerprint on the 
sensor or approach a user card. The output state will be switched from the 
current one. 

 

Switch output state with master card:  

Approach the master card and remove it after 5 double beeps. Within a 
period of three seconds approach a user card or place a user fingerprint on 
the sensor. The output state will be switched from the current one. 

 

Function 6) Delete a fingerprint or a lost card 

Delete the next fingerprint or card on the list. Use this function if you wish to 
delete a fingerprint or lost card from the controller. In order to use this 
function you must maintain a list of registered fingerprints and cards, 
arranged by order of registrations so that you can find the fingerprint or 
card, which was registered before the one you wish to delete. 

Delete a fingerprint or a lost card with master fingerprint: 

Place the master fingerprint six times on the sensor and remove it (6 double 
beeps). Within a period of three seconds place a user fingerprint on the 
sensor or approach a card, which was registered 

before

 the one you wish to 

delete. This will delete the next fingerprint or card on the list. Next 
registered fingerprint or card will take the position of a deleted fingerprint or 
deleted card. 

 

Delete a fingerprint or a lost card with master card: 

Approach the master card and remove it after 6 double beeps. Within a 

period of three seconds approach the user card or place a user fingerprint on 
the sensor, which was registered 

before

 the one you wish to delete. This will 

delete the next fingerprint or card on the list. Next registered card or 
fingerprint will take the position of a deleted card or deleted fingerprint. 

 

Function 7) Delete a fingerprint or a lost card 

Delete the previous fingerprint or card on the list. Use this function if you 
wish to delete a fingerprint or lost card from the controller. In order to use 
this function you must maintain a list of registered fingerprints or cards, 
arranged by order of registrations so that you can find the fingerprint or 

card, which was registered after the one you wish to delete. 

Delete a fingerprint or a lost card with master fingerprint: 

Place the master fingerprint seven times on the sensor and remove it (7 
double beeps). Within a period of three seconds place a user fingerprint on 
the sensor or approach a card, which was registered 

after

 the one you wish 

to delete. This will delete the previous fingerprint or card on the list. Next 
registered fingerprint or card will take the position of a deleted fingerprint or 
deleted card. 

 

Delete a fingerprint or a lost card with master card: 

Approach the master card and remove it after 7 double beeps. Within a 
period of three seconds approach the user card or place a user fingerprint on 
the sensor, which was registered 

after

 the one you wish to delete. This will 

delete the previous fingerprint or card on the list. Next registered card or 
fingerprint will take the position of a deleted card or deleted fingerprint. 
 

 

 

 

 

Function 9) Switch to Wiegand 26-bit, access controller or 

back to standalone controller 

Switch the controller to a Wiegand 26-bit reader or an access controller. To 
change the controller back to a standalone controller from an access 
controller, you need to make a “brainwash” with the Codeks or Codeks 
Device Manager software. 

Switch with master fingerprint or master card:

  

Place the master fingerprint nine times on the sensor and remove it (9 
double beeps) or approach the master card and remove it after 9 double 
beeps. The controller will start to beep every second. Each beep presents a 
different function, which is selected with a user fingerprint or user card. 

Standalone controller

 – Place the user fingerprint on the sensor or 

approach a user card before 1 beep.

 

Wiegand 26-bit reader

 – Place the user fingerprint on the sensor or 

approach a user card after 1 beep. 

Access controller

 – Place the user fingerprint on the sensor or approach a 

user card after 4 beeps.

 

 

Function 13) Delete all 

Reset/ delete all data to default. 

Delete all with master fingerprint: 

Place the master fingerprint thirteen times on the sensor and remove it (13 

double beeps). The controller will start to beep every second. After three 
beeps place a user fingerprint on the sensor or approach a user card for 
confirmation.  

 
Delete all with master card: 

Approach the master card and remove it after 13 double beeps. The 
controller will start to beep every second. After three beeps approach a user 
card or place a user fingerprint on the sensor for confirmation. 
 

Delete all with the Codeks Device Manager program:  

Set the Rex to the default settings by using the Codeks Device Manager 
program. Connect the Rex via RS485 communication line to the Spider 
(communication converter, USB or NET). Connect the Spider to the 
computer. In Codeks Device Manager, find the device and perform the "Brain 
Wash" function which sets the device to its default settings. 

 

Default settings 

A three-second pulse, five-second open time, four-second pre-alarm time, 
door status switch input and push button input have NO contact; output is 
set for fail secure el. strike. The controller is in standalone mode.

 

 

Function 15) Sound, alarm output, door status switch input 

(NC or NO), set the time in minutes or seconds (function 2, 

3, 4) 

Turn on/off the sound (beep) which is heard as a pre-alarm and alarm, when 
a user fingerprint or user card is registered.  
Turn on/off the accelerometer which triggers the alarm output (output1, O1, 
wire 4) when the controller is moved.  
Set the Input0/I0/wire 5 to normally closed (NC) or normally opened (NO, 
default).  
Set the time in functions 2, 3, 4 in minutes or seconds.  

Set with master fingerprint or master card: 

Place the master fingerprint fifteen times on the sensor and remove it (15 
double beeps) or approach the master card and remove it after 15 double 

beeps. The controller will start to beep every second. Each beep presents a 
different function, which is selected with a user fingerprint or user card. 
 

Beep 

Specification 

No beep 

Sound is OFF 
Tamper is OFF 
Door status switch input-normally opened (NO) 
Time is set in seconds  

1. beep 

Sound is ON 
Tamper is OFF 
Door status switch input-normally opened (NO) 
Time is set in seconds 

2. beep 
 

Sound is OFF 
Tamper is ON 
Door status switch input-normally opened (NO) 
Time is set in seconds 

3. beep 

Sound is ON 
Tamper is ON 
Door status switch input-normally opened (NO) 

Time is set in seconds 

4. beep 

Sound is OFF 

Tamper is OFF 
Door status switch input-normally closed (NC) 
Time is set in seconds 

Содержание REX F-0-9

Страница 1: ... of UTP cables for the positive pole and one for the negative pole The cable length between power supply and the controller should not exceed 50m Take into consideration that a 0 22mm2 cable has a resistance of approximately 9 ohm per 100m The power supply at the end of cable should be a minimum of 9V If you are using el strike it is highly recommended that the voltage drop is calculated At greate...

Страница 2: ...e process with the same fingerprint this fingerprint will be deleted Next registered fingerprint will take the first available position on the list or position of the deleted fingerprint If you would like to delete the fingerprint of the user that no longer exists you must maintain a list of registered fingerprints arranged in order of registrations positions functions 6 and 7 Function 2 Pulse tim...

Страница 3: ...place a user fingerprint on the sensor confirmation Delete all with the Codeks Device Manager program Set the Rex to the default settings by using the Codeks Device Manager program Connect the Rex via RS485 communication line to the Spider communication converter USB or NET Connect the Spider to the computer In Codeks Device Manager find the device and perform the Brain Wash function which sets th...

Страница 4: ...d Jantar software Up to 128 controllers can be lined up into one communication line The maximum length of the communication line is 1000 cable meters It is recommended that you use an FTP or S FTP cable Only a serial connection of controllers in a single communication line is allowed Star parallel connection is not allowed All shields of S FTP cables must be wired together and at one point connect...

Страница 5: ...of 9V If you are using el strike it is highly recommended that the voltage drop is calculated At greater distances a thicker cable of 0 5mm2 or more should be used wherever possible If the load is for example 0 5A with el strike then on the 0 22mm2 cable voltage drop will be 4 5V at 100m For the device with 60mA consumption the voltage drop is 0 5V Reading distance depends on where the controller ...

Страница 6: ...led the controller signals with a longer beep If the registration is successful the user fingerprint is registered and with it the user can open output on the controller If you repeat the process with the same fingerprint this fingerprint will be deleted Next registered fingerprint or card will take the first available position on the list or position of the deleted fingerprint If you would like t...

Страница 7: ... sensor or approach a card which was registered after the one you wish to delete This will delete the previous fingerprint or card on the list Next registered fingerprint or card will take the position of a deleted fingerprint or deleted card Delete a fingerprint or a lost card with master card Approach the master card and remove it after 7 double beeps Within a period of three seconds approach th...

Страница 8: ... 255 to any number between 1 and 254 If you have more controllers on the communication line don t duplicate addresses Add them one by one on the communication line because every controller has address 255 by default Communication Connect the controller to the computer with one of the power supplies with built in communication converter from the Spider family Spider W5 USB Spider W5 NET Spider W40 ...

Отзывы: