REX F-0-9– Standalone or Access Controller
3/2015
Black line
www.jantar.si
14. beep
Sound is OFF
Tamper is ON
Door status switch input- normally closed (NC)
Time is set in minutes
15. beep
Sound is ON
Tamper is ON
Door status switch input- normally closed (NC)
Time is set in minutes
Function 16) Reset
“HARD” reset. Use it instead off manual reset (power off/on).
Reset with master fingerprint:
Place the master fingerprint sixteen times on the sensor and
remove it (16 double beeps).The controller will start to beep every
second. After three beeps place a user fingerprint on the sensor for
confirmation.
AS AN ACCESS CONTROLLER
As an access controller, it is intended for controlling entries, exits
and passes of users in the system and controlling sliding doors,
ramp, el. strike, turning alarm on/off… It needs to be set with
CODEKS software.
The controller switches to access controller when tables are
sent by the software or when it is set to mode 4 with
function 9. Change the controller’s address from 255 to any
number between 1 and 254. If you have more controllers on
the communication line, don’t duplicate addresses. Add
them one by one on the communication line, because every
controller has address 255 by default.
Communication
Connect the controller to the computer with one of the power
supplies, with built-in communication converter, from the Spider
family: Spider W5-USB, Spider W5-NET, Spider W40+NET.
The RS485 communication bus is used between the controllers and
Jantar software. Up to 128 controllers can be lined up into one
communication line. The maximum length of the communication
line is 1000 cable meters. It is recommended that you use an FTP
or S-FTP cable. Only a serial connection of controllers in a single
communication line is allowed.
Star (parallel) connection is not
allowed
.
All shields of S-FTP cables must be wired together and at
one
point
connected to the earth. Individual connections to the earth
are not allowed. Do not connect the shield of the cable to the
ground of the controller.
In the event of problems in communication, a termination
resistor needs to be added. We recommend using 120 Ohm
resistors on each side of the cable. Converters are, on the
RS485 side, protected with slow-blow fuses and transient
voltage suppressors.
Changing back to standalone controller from access
controller:
In the Codeks Device Manager software do the “Brainwash” of the
controller. Address of the controller’s switches back to 255.
Correct and incorrect position of the finger on the sensor
Correct: Incorrect:
ORDERING CODES
REX
[box]-[card]-[software]
Box:
F
Card:
0
– only fingerprint reader
Software:
9
– CODEKS
Code
Description
REX F-0-9
Standalone or access controller in
F
box, with
fingerprint reader, for CODEKS software
OTHER
Warranty only applies when the controller Rex is used with power
supply or/and communication converter from the Spider family.
Please read through our warranty and disclaimer statements.
Connection scheme and additional support for the use of this
product can be found on:
CONTACT:
Jantar d.o.o.
Kranjska cesta 24
4202 Naklo
SLOVENIA
mail: