Adjusting the Needle Height
Tool required: #3 Screwdriver
NOTE
: This adjustment must be completed with the front frame cover on.
Check
The needle height must be set so that when
viewed from behind with the hook point flush
with the right side of the needle, the bottom of
the hook point should be 1.0 mm above the top
of the needle eye.
1.0 mm
If needle height adjustment is
necessary
1. Lower the needle bar to its lowest position.
2. Insert a screwdriver through the access hole
.
Â
IMPORTANT: Hold the needle bar with
your other hand to provide resistance
against the adjustment, so the needle
bar will not fall down out of the driver.
3. Loosen the screw slightly so that the needle
bar can be wiggled up or down to the
correct position.
Access hole