QMP16SU Service Manual
| 35
X-axis adjustment (left to right)
NOTE
: This adjustment is done with the
front frame cover on.
The primary adjustment is accomplished using the
right side of the head frame shown. Loosen the
screws on the left side to allow movement of the
head frame.
1. Loosen screws F, G and H through access holes
two or three turns.
2. Loosen screws D and E two or three turns; then
back off screw C a little.
X-axis access holes
3. Push the head frame back against the main
frame so that screw C touches the main frame.
While pushing the head frame back, adjust
screw C to bring the needle to center in the
needle plate.
4. Gently tighten screw E until it lightly touches
the main frame.
5. Tighten screw D.
NOTE
: If the needle changes, repeat the
process.
6. Repeat the process on the left side of the head
frame.
NOTE
: If the needle changes, repeat the
process.
F
H
G
D
C
E
NOTE
: The picture shows the cover off for
illustration purposes only.
Содержание QMP16SU