6. ZEROING THE NEEDLE
Check : 1. Select straight stitch position.
2. Sewing a line straight stitch.
3. Shall be no or minimul movement below
0.3 mm.
Adjustment : 1. Remove rear cover.
2. Select straight stitch position.
3. Loosen screw (or nut ) (A).
4. Remove connecting plate (B) so that no or
minimul movement of needle bar.
5. Tighten screw (or nut ) (A).
(ALL MODELS)
A
B
B
A
C
Model
Model
7