5
6. Feed Lifting Cam Timing
To check:
[1] Lower the needle bar until the point of needle is level
with the upper surface of the needle plate (1) (1600P-
DB/DBX) or 0.4 mm below the needle plate (1600P).
[2] The top of the feed dogs (2) should be 0 - 0.1 mm
above the needle plate.
To adjust:
[1] Remove the base and lay the machine on its back.
* You may set the stitch length dial at any position.
[2] Loosen the setscrew (3).
Lower the needle bar until the needle point is level
with the needle plate (1)(1600P-DB/DBX) or 0.4 mm
below the needle plate (1600P).
[3] Loosen the setscrew (4).
[4] If the feed dogs are higher, turn the feed lifting cam
(5) in the direction
A.
If the feed dogs are lower, turn the feed lifting cam (5)
in the direction
B.
[5] Tighten the setscrew (3) and attach the base.
(1)
(4)
(2)
(1)
(1)
(5)
A
B
0.4 mm
0 - 0.1 mm
1600P-DB/DBX
1600P
(3)
(4)