www.janitza.com
87
UMG 512-PRO
Pulse length
The pulse length is valid for both pulse outputs
and must be set via the GridVis® software.
The typical pulse duration for S0 pulses is 30 ms.
Pulse pause
The pulse pause must be at least as large as the
selected pulse length.
The pulse pause depends on the measured ener-
gy, for example, and can be hours or days.
Pulse length
10 ms .. 10 s
Pulse pause
>10 ms
Fig. Schematic representation of a digital pulse
The values in the table for the maximum number
of pulses per hour result from the minimum pulse
length and the minimum pulse pause.
Pulse
length
Pulse
pause
Max. pulses/h
10 ms
10 ms
180,000 pulses/h
30 ms
30 ms
60,000 pulses/h
50 ms
50 ms
36,000 pulses/h
100 ms
100 ms
18,000 pulses/h
500 ms
500 ms
3,600 pulses/h
1 s
1 s
1,800 pulses/h
10 s
10 s
180 pulses/h
Tab. Examples of the maximum possible number of pulses
per hour
INFORMATION
The pulse interval is proportional to the power
within the selected settings.
INFORMATION
When programming with GridVis®, you are giv-
en a selection of work values derived from the
power values (see www.janitza.com).
Pulse valency
The pulse valency specifies how much energy
(Wh or varh) should correspond to one pulse.
The pulse valency is determined by the maximum
connected load and the maximum number of
pulses per hour.
If you indicate the pulse valency with:
·With a positive sign, pulses are only output if the
measured value also has a positive sign.
·With a negative sign, pulses are only output if the
measured value also has a negative sign.
INFORMATION
Since the active energy meter operates with
a reverse running stop, the device only sends
pulses when electrical energy is consumed.
INFORMATION
Since the reactive energy meter operates with
a reverse running stop, the device only sends
pulses when there is an inductive load.
Содержание UMG 512-Pro
Страница 23: ...www janitza com 23 UMG 512 PRO ...
Страница 27: ...www janitza com 27 UMG 512 PRO ...
Страница 47: ...www janitza com 47 UMG 512 PRO ...
Страница 89: ...www janitza com 89 UMG 512 PRO ...
Страница 96: ...UMG 512 PRO www janitza com 96 Fig IEC 61000 2 4 Watchdog parameters with traffic light principle report ...
Страница 97: ...www janitza com 97 UMG 512 PRO Fig IEC61000 2 4 PQ indicator parameters with traffic light principle snapshot ...
Страница 111: ...www janitza com 111 UMG 512 PRO 15 9 Dimensional drawings Fig View from the side Fig View from below ...
Страница 119: ...www janitza com 119 UMG 512 PRO ...