Jandy WFTR Скачать руководство пользователя страница 4

Page 4 

ENGLISH

  

 

Jandy

®

 Pro Series Water Feature Pump   

|

   Installation and Operation Manual

Section 1. Important Safety Instructions 

READ AND FOLLOW ALL INSTRUCTIONS

1.1  Safety Instructions

All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. 

When installing and using this electrical equipment, basic safety precautions should always be followed, including the 

following:

 

WARNING

RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS INJURY 

OR DEATH. 

Do not block pump suction as this can cause severe injury or death. Do not use this pump for 

wading pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two 

functioning suction outlets.  Suction outlet (drain) covers must be certified to the latest published version of ANSI/

ASME A112.19.8. 

 

WARNING

To reduce the risk of injury, do not permit children to use this product.

 

WARNING

To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full 

flow) valve position with the pump running.

 

WARNING

Jandy Pro Series pumps are powered by a high voltage electric motor and must be installed by a licensed or 

certified electrician or a qualified swimming pool service technician.

 

WARNING

Due to the potential risk of fire, electric shock, or injuries to persons, Jandy

 

Pumps must be installed in 

accordance with the National Electrical Code (NEC), all local electrical and safety codes, and the Occupational 

Safety and Health Act (OSHA). Copies of the NEC may be ordered from the National Fire Protection Association, 

470 Atlantic Ave., Boston, MA 02210, or received by contacting your local government inspection agency.

 

WARNING

Incorrectly installed equipment may fail, causing severe injury or property damage.

 

WARNING

•  Do not connect the system to an unregulated city water system or other external source of pressurized water 

producing pressures greater than 35 PSI.

•  Trapped air in system can cause the filter lid to be blown off, which can result in death, serious personal injury, 

or property damage. Be sure all air is out of the system before operating.

Содержание WFTR

Страница 1: ...oduct read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Imprope...

Страница 2: ......

Страница 3: ...Introduction 7 2 2 Description 7 Section 3 Installation 8 3 1 Plumbing 8 3 2 Electrical Installation 9 3 2 1 Voltage Checks 9 3 3 Pressure Testing 10 Section 4 Operation 11 4 1 Start up 11 Section 5 S...

Страница 4: ...ty damage or injury do not attempt to change the backwash multiport slide or full flow valve position with the pump running WARNING Jandy Pro Series pumps are powered by a high voltage electric motor...

Страница 5: ...visually check system to be sure it is ready for operation NOTICE These parameters apply to Zodiac equipment only For non Zodiac equipment consult equipment manufacturer CAUTION Do not start pump dry...

Страница 6: ...wo 2 main drains run into a single suction line the single suction line may be equipped with a valve that will shut off both main drains from the pump The system shall be constructed such that it shal...

Страница 7: ...trength and corrosion resistance The pump is driven by an electric motor directly attached to the pump impeller As the electric motor turns it causes the impeller to turn which forces water to flow th...

Страница 8: ...nds bolting the pump directly to the foundation 5 The pump foundation must have adequate drainage to prevent the motor from getting wet Protect the pump from the rain and sun 6 Proper ventilation is r...

Страница 9: ...Ball Valves typically have the best flow capabilities 7 Use the fewest fittings possible Every additional fitting has the effect of moving the equipment farther away from the water NOTE If more than 1...

Страница 10: ...o operate simultaneously with the pump such as a chlorinating device or heater to both the pump and motor and will void the warranty 3 2 3 Electrical Wiring WARNING To avoid risk of property damage se...

Страница 11: ...takes to prime will depend on the elevation and length of pipe used on the suction supply pipe See Section 3 1 3 3 Installation Recommendations for proper elevation and pipe size 9 If the pump does no...

Страница 12: ...s have been returned to the proper position for normal operation 9 If a filter is installed in the system open the pressure release valve on the filter and make sure it is clean and ready for operatio...

Страница 13: ...to tighten the union If this does not stop the air leak turn off the pump Loosen both unions and slide the pump out of the way Remove clean and re install both union o rings Reposition the pump next t...

Страница 14: ...Steps 2 through 4 the pump will need to be disassembled in order to access the inlet and outlet of the impeller 6 2 2 Impeller Removal WARNING While servicing the pump switch off the circuit breakers...

Страница 15: ...the impeller from the motor shaft with your hand Since the impeller is a right hand thread turn the impeller counter clockwise to unscrew it 10 Inspect the impeller and diffuser for signs of rubbing a...

Страница 16: ...ou removed the diffuser o ring make sure you install it into the proper groove see Figure 5 If grease is used to retain the o ring it must be silicone based Do not use petroleum based grease It will d...

Страница 17: ...nd following the steps in Section 6 2 3 Impeller Replacement 6 2 5 Motor Replacement CAUTION To ensure continued safety and reliable operation Zodiac Pool Systems Inc requires that you replace the mot...

Страница 18: ...All R0445200 3 Impeller Diffuser w Screw and O ring WFTR 1 0 R0449502 3 Impeller Diffuser w Screw and O ring WFTR 1 5 R0449503 3 Impeller Diffuser w Screw and O ring WFTR 2 5 R0449505 3 Screw w O rin...

Страница 19: ...s Water Feature Pump Installation and Operation Manual Figure 11 WFTR Exploded View 7 2 Exploded View 14 11 8 9 12 10 qty 2 4 15 3 6 11 3 4 14 2 5 2 2 qty 8 16 qty 8 3 15 4 qty 2 15 qty 2 2 13 1 qty 4...

Страница 20: ...eries High Head Pumps WFTR 0 10 20 30 40 50 60 70 80 90 100 110 120 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 0 5 10 15 20 25 30 35 40 45 50 WFTR80 1...

Страница 21: ...Carton Weight Overall Length A WFTR80 1 00 230 115 7 1 14 2 2 2 41 2 28 WFTR120 1 50 230 115 8 0 16 2 2 42 6 29 WFTR160 2 50 230 11 5 2 3 48 6 30 NOTE When installing the pump leave a minimum of 2 fe...

Страница 22: ...eries Water Feature Pump Installation and Operation Manual 7 5 Replacement Motor Guide WFTR Replacement Motor Guide Pump Model A O Smith Century Emerson Motor Technologies WFTR80 B853 EB853 WFTR120 B8...

Страница 23: ...Page 23 ENGLISH Jandy Pro Series Water Feature Pump Installation and Operation Manual NOTES...

Страница 24: ...ZodiacPoolSystems com ZODIAC is a registered trademark of Zodiac International S A S U used under license All trademarks referenced herein are the property of their respective owners 2012 Zodiac Pool...

Отзывы: