Section 4.  Operation

4.1 Start-up

CAUTION

Never run the pump without water. Running the pump 

“dry” for any length of time can cause severe damage 

to both the pump and motor and will void the warranty

If this is a new pool installation, make sure all piping 

is clear of construction debris and has been properly 

pressure tested. If a filter is installed in the system, it 

should be checked for proper installation, verifying that 

all connections and clamps are secure according to the 

manufacturer’s recommendations.

 WARNING

To avoid risk of damage or injury, verify that all power 

is turned off before starting this procedure.

1. 

If a filter is intalled in the system, release all 

pressure from the system and open the filter 

pressure release valve.

2. 

If the pump is located below the water level of 

the pool, opening the lid should allow water to 

fill the basket area. If a filter is installed in the 

system, opening the filter pressure release valve 

will prime the pump with water.

3. 

If the pump is located above the water level of 

the pool, remove the lid and fill the basket with 

water before starting the pump.

4. 

To prevent air from leaking into the system, 

remove any debris around the lid seal seat. 

5. 

Hand-tighten the lid to make an air tight seal. 

Do 

not use any tools: hand-tighten only.

 Ensure that 

the lid is secure. Make sure all valves are open 

and the unions are tight.

6. 

Restore power to the pump, then turn on the 

pump.

7. 

If a filter is installed in the system, when all the 

air has left the filter, close the filter pressure 

release valve.

8. 

The pump should prime. The time it takes to 

prime will depend on the elevation and length of 

pipe used on the suction supply pipe. See  

Section 3.1.3.3, Installation Recommendations 

for proper elevation and pipe size.

9. 

If the pump does not prime and all the 

instructions to this point have been followed, 

check for a suction leak and then repeat Steps 2 

through 7.

10.  For technical assistance, contact Technical 

Support Department at (800) 822-7933. 

Section 5.  Service and 

Maintenance

5.1  Routine Maintenance

Inspect the pump basket for debris by looking through 

the clear pump lid. Remove any debris, because as debris 

accumulates, it will begin to block the flow of water 

through the pump. Keep the basket clean to improve the 

performance of the pump. 

1. 

Turn off the power to the pump. If the pump is 

located below water level, close the isolation 

valves on the suction and discharge sides of the 

pump to prevent backflow of water. 

2. 

Turn the lid's locking ring counter-clockwise 

until the 'START' marking aligns with the ports. 

Carefully remove the locking ring and the lid.

CAUTION

A misaligned basket will cause the lid to be improper-ly 

seated, allowing an air leak, which could result in pump 

damage.

3. 

Lift the basket out of the pump. Dispose of all 

debris and thoroughly clean the basket, making 

sure all the holes are open. Using a garden hose, 

spray the basket from the outside to help clear the 

holes. Remove any remaining debris by hand.

4. 

Replace the basket in the pump by aligning the 

open section of the basket with the inlet pipe. If 

aligned properly, the basket will drop easily into 

place. 

Do not force it into place.

5. 

Remove the lid seal and remove debris around 

the lid groove, as this will cause air leaks in the 

system. Clean the lid groove and the lid seal.

6. 

Note that one (1) side of the lid seal has two (2) 

ribs and the other has one (1). Place the side with 

two (2) ribs into the groove. See Figure 2.

Содержание WFTR

Страница 1: ...oduct read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Imprope...

Страница 2: ......

Страница 3: ...Introduction 7 2 2 Description 7 Section 3 Installation 8 3 1 Plumbing 8 3 2 Electrical Installation 9 3 2 1 Voltage Checks 9 3 3 Pressure Testing 10 Section 4 Operation 11 4 1 Start up 11 Section 5 S...

Страница 4: ...ty damage or injury do not attempt to change the backwash multiport slide or full flow valve position with the pump running WARNING Jandy Pro Series pumps are powered by a high voltage electric motor...

Страница 5: ...visually check system to be sure it is ready for operation NOTICE These parameters apply to Zodiac equipment only For non Zodiac equipment consult equipment manufacturer CAUTION Do not start pump dry...

Страница 6: ...wo 2 main drains run into a single suction line the single suction line may be equipped with a valve that will shut off both main drains from the pump The system shall be constructed such that it shal...

Страница 7: ...trength and corrosion resistance The pump is driven by an electric motor directly attached to the pump impeller As the electric motor turns it causes the impeller to turn which forces water to flow th...

Страница 8: ...nds bolting the pump directly to the foundation 5 The pump foundation must have adequate drainage to prevent the motor from getting wet Protect the pump from the rain and sun 6 Proper ventilation is r...

Страница 9: ...Ball Valves typically have the best flow capabilities 7 Use the fewest fittings possible Every additional fitting has the effect of moving the equipment farther away from the water NOTE If more than 1...

Страница 10: ...o operate simultaneously with the pump such as a chlorinating device or heater to both the pump and motor and will void the warranty 3 2 3 Electrical Wiring WARNING To avoid risk of property damage se...

Страница 11: ...takes to prime will depend on the elevation and length of pipe used on the suction supply pipe See Section 3 1 3 3 Installation Recommendations for proper elevation and pipe size 9 If the pump does no...

Страница 12: ...s have been returned to the proper position for normal operation 9 If a filter is installed in the system open the pressure release valve on the filter and make sure it is clean and ready for operatio...

Страница 13: ...to tighten the union If this does not stop the air leak turn off the pump Loosen both unions and slide the pump out of the way Remove clean and re install both union o rings Reposition the pump next t...

Страница 14: ...Steps 2 through 4 the pump will need to be disassembled in order to access the inlet and outlet of the impeller 6 2 2 Impeller Removal WARNING While servicing the pump switch off the circuit breakers...

Страница 15: ...the impeller from the motor shaft with your hand Since the impeller is a right hand thread turn the impeller counter clockwise to unscrew it 10 Inspect the impeller and diffuser for signs of rubbing a...

Страница 16: ...ou removed the diffuser o ring make sure you install it into the proper groove see Figure 5 If grease is used to retain the o ring it must be silicone based Do not use petroleum based grease It will d...

Страница 17: ...nd following the steps in Section 6 2 3 Impeller Replacement 6 2 5 Motor Replacement CAUTION To ensure continued safety and reliable operation Zodiac Pool Systems Inc requires that you replace the mot...

Страница 18: ...All R0445200 3 Impeller Diffuser w Screw and O ring WFTR 1 0 R0449502 3 Impeller Diffuser w Screw and O ring WFTR 1 5 R0449503 3 Impeller Diffuser w Screw and O ring WFTR 2 5 R0449505 3 Screw w O rin...

Страница 19: ...s Water Feature Pump Installation and Operation Manual Figure 11 WFTR Exploded View 7 2 Exploded View 14 11 8 9 12 10 qty 2 4 15 3 6 11 3 4 14 2 5 2 2 qty 8 16 qty 8 3 15 4 qty 2 15 qty 2 2 13 1 qty 4...

Страница 20: ...eries High Head Pumps WFTR 0 10 20 30 40 50 60 70 80 90 100 110 120 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 0 5 10 15 20 25 30 35 40 45 50 WFTR80 1...

Страница 21: ...Carton Weight Overall Length A WFTR80 1 00 230 115 7 1 14 2 2 2 41 2 28 WFTR120 1 50 230 115 8 0 16 2 2 42 6 29 WFTR160 2 50 230 11 5 2 3 48 6 30 NOTE When installing the pump leave a minimum of 2 fe...

Страница 22: ...eries Water Feature Pump Installation and Operation Manual 7 5 Replacement Motor Guide WFTR Replacement Motor Guide Pump Model A O Smith Century Emerson Motor Technologies WFTR80 B853 EB853 WFTR120 B8...

Страница 23: ...Page 23 ENGLISH Jandy Pro Series Water Feature Pump Installation and Operation Manual NOTES...

Страница 24: ...ZodiacPoolSystems com ZODIAC is a registered trademark of Zodiac International S A S U used under license All trademarks referenced herein are the property of their respective owners 2012 Zodiac Pool...

Отзывы: