  CAUTION

A ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. The 
conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures 
containing other conductors unless the additional conductors are also protected by a ground-fault circuit-
interrupter. Refer to local codes for complete details.

  CAUTION

A terminal bar marked "GROUND" is provided within the power center. To reduce the risk of electrical shock, 
connect this terminal bar to the grounding terminal of your electric service or supply panel with a continuous 
copper conductor having green insulation and one that is equivalent in size to the circuit conductors supplying this 
equipment, but no smaller than no. 12 AWG (3.3mm). In addition, a second wire connector should be bonded with 
a no. 8 AWG (4.115mm) copper wire to any metal ladders, water pipes, or other metal within five (5) feet (1.52m) 
of the tub.

SAVE THESE INSTRUCTIONS

  WARNING

People with infectious diseases should not use a spa or hot tub.
To avoid injury, exercise care when entering or exiting the spa or hot tub.
Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible 
drowning.
Pregnant or possibly pregnant women should consult a physician before using a spa or hot tub. 
Water temperature in excess of 100

°

F/38

°

C may be injurious to your health. 

Before entering a spa or hot tub measure the water temperature with an accurate thermometer. 
Do not use a spa or hot tub immediately following strenuous exercise.
Prolonged immersion in a spa or hot tub may be injurious to your health.
Do not permit any electric appliance (such as a light, telephone, radio, or television) within 5 feet (1.5 m) of a spa 
or hot tub.
The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.
Water temperature in excess of 100

°

F/38

°

C may be hazardous to your health. 

  AVERTISSEMENT

Les personnes atteintes de maladies infectieuses ne devraient pas utiliser une cuve de relaxation.
Pour 

é

viter des blessures, user de prudence en entrant dans une cuve de relaxation et en sortant.

Pour 

é

viter l

’é

vanouissement et la noyade 

é

ventuelle, ne prendre ni drougue ni alcool avant d

’

utiliser une cuve de 

relaxation ni quand on s

’

y trouve.

Les femmes enceintes, que leur grossesse soit con

 

 rm

é

e ou non, devraient consulter un m

é

decin avant d

’

utiliser 

une cuve de relaxation.
Il peut 

ê

tre dangereux pour la sant

é

 de se plonger dans de l

’

eau 

à

 plus de 38

°

C/100

°

F.

Avant d

’

utiliser une cuve de relaxation mesurer la t

é

mperature de l

’

eau 

à

 l

’

aide d

’

un thermom

è

tre pr

é

cis.

Ne pas utiliser une cuve de relaxation imm

é

diatement apr

è

s un exercice fatigant.

L

’

utilisation prolong

é

e d

’

une cuve de relaxation peut 

ê

tre dangereuse pur la sant

é

.

Ne pas placer d'appareil 

é

lectrique (luminaire, t

é

l

é

phone, radio, t

é

l

é

viseur, etc) 

à

 moins de 1.5m de cette cuve de 

relaxation.
La consommation d

’

alcool ou de drogue augmente consid

é

rablement les risques d

’

hyperthermie mortelle dans 

une cuve de relaxation.
Il peut etr

ê

 dangereux pour la sant

é

 de se plonger dans de l

’

eau 

à

 plus de 38

°

C/100

°

F.

Attention installer:

Install to provide drainage of compartment for electrical components.

  WARNING

To avoid injury ensure that you use this control system to control only packaged pool/spa heaters which have built-
in operating and high limit controls to limit water temperature for pool/spa applications.  This device should not be 
relied upon as a safety limit control.

Содержание RS-P4

Страница 1: ...s These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not...

Страница 2: ......

Страница 3: ...0 4 2 Restarting the System Clear Memory Menu 23 4 3 PDA System Defaults and General Modes 23 4 4 PDA Handheld Remote Menu Flow Chart 25 Section 5 Troubleshooting 26 5 1 PDA Quick Troubleshooting Guid...

Страница 4: ...regnant or possibly pregnant women should limit spa water temperatures to 100 F 38 C c Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since...

Страница 5: ...your health Do not permit any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub The use of alcohol drugs or medication can greatly increase the r...

Страница 6: ...gital Assistant PDA System Sub Assembly Power Centers Sold Separately Standard Power Center with mounting brackets Sub Panel Power Center with mounting brackets and circuit breaker mounting plate Two...

Страница 7: ...VAC 1 HP 120 VAC 1500 Watts Incandescent Low Voltage Class Two 1 A 24 VAC Service Switch All Circuits located at Power Center in Service Mode Dimensions Standard Power Center 5 14 13 Sub Panel Power...

Страница 8: ...l and spa consult the Jandy Valve Actuator Installation and Operation Manual to ensure that the JVA s are synchronized and rotate properly Please consult the Jandy Valve Plumbing Manual for further ex...

Страница 9: ...Filter Pump Pool Intake Spa Intake Spa Return Pool Return Check Valve Spa Make up Booster Pump Filter Filter Pump Pool Intake Spa Intake Spa Return Pool Return Check Valve Spa Make up Energy Filter Cl...

Страница 10: ...lack White Primary Low voltage raceway do not run high voltage in this com partment From Main Power Ground White White Black Black Transformer Earth Ground Breaker Panel To 120 VAC Breaker Neutral Bla...

Страница 11: ...be controlled connect line power to the two 2 line terminals and connect equipment power to the two 2 load terminals on the same relay For each piece of 120 volt equipment connect power to a line ter...

Страница 12: ...2 volt light a 120 volt 12 volt step down AC transformer listed certified for the application must be used For more information about 12 volt installations refer to the Jandy Digital Color Changing Un...

Страница 13: ...Page 13 Figure 5 120 Volt Jandy Pool and Spa Light Wiring Diagram Figure 6 12 Volt Jandy Pool and Spa Light Wiring Diagram...

Страница 14: ...es are kept from being pinched or damaged CAUTION DO NOT INSTALL BATTERY until ready to power up system 3 3 2 PDA J Box Cable Connection to Power Center PCB Make provision for the cable to be run betw...

Страница 15: ...high limit or pressure switches 4 Turn the heater thermostat s to maximum setting 5 Turn the heater switch to the ON position For dual thermostat heaters turn switch to Spa position Figure 9 Lite2 He...

Страница 16: ...nction configuration connect the orange black and black orange wires to one contact and the yellow black wire to the other contact see Figure 15 Limit Switch Factory Installed Wire Nut R Limit Switch...

Страница 17: ...ndard relay then connect the relay to the solar pump output on the PCB Set the time to 11 59 PM at 12 00 AM the AquaLink RS will auto relabel Solar as Heat Pump Otherwise the AquaLink RS will auto rel...

Страница 18: ...nsor Green 10 Pin Terminal Bar NOTE Do not coil the JVA wires inside Power Center To shorten the wire remove the JVA cover and disconnect the wire Shorten strip and reconnect 3 For alternate plumbing...

Страница 19: ...or your AquaLink RS PDA system can be changed The Power Center Transceiver and the PDA Transceiver J box must be set to the same RF channel 1 At the Transceiver J box remove the cover to expose the PC...

Страница 20: ...light the desired RF channel Then press SELECT 4 When the RF channel is selected the following message appears on the PDA display screen Set slide switch on J Box PCB to the LEARN MODE 5 At the PCB in...

Страница 21: ...re 25 Use the UP or DOWN button to highlight either POOL or SPA and press SELECT Use the UP or DOWN button to increase or decrease the temperature and press SELECT Use the BACK button to return to the...

Страница 22: ...ce of equipment Highlight a device and press SELECT X means the device has been assigned NOTE The filter pump is always assigned to freeze protection 4 1 6 Assign JVAs Menu Highlight MENU and press SE...

Страница 23: ...or pool spa only models Button 2 Spa Heater Temp1 pool spa only models Button 3 AUX1 Button 4 AUX2 Default Freeze Protection Settings FILTER PUMP freeze protection ON ALL OTHER EQUIPMENT freeze protec...

Страница 24: ...pecial Note to Startup Person The AquaLink RS PDA allows two 2 options for operating the pool equipment on the first day of operation Option 1 Once all programming of equipment is completed the AquaLi...

Страница 25: ...Page 25 4 4 PDA Handheld Remote Menu Flow Chart Items Seen Only With Optional Equipment Mode Only Displayed When DIP Switch 3 is Set to ON...

Страница 26: ...the four conductor cable Also check the installation of the PPD on the power center PCB If the PPD is not seated correctly the system will not communicate PDA Handheld Remote backlight is on and the s...

Страница 27: ...itch 1 Turn on power and test system Cannot assign cleaner JVA DIP switches not set correctly DIP switch 1 must be off and DIP switch 7 must be on to assign the cleaner JVA to an auxiliary System come...

Страница 28: ...Page 28 Section 6 Power Center Wiring Diagram...

Страница 29: ...IMPORTANT You must also install a Jandy Two Speed Relay DIP 3 ON AUX 3 Controls Spa Spillover Operates with Pool Spa Combination Turn this switch ON and when the AUX 3 button on the AquaLink RS PDA o...

Страница 30: ...down disabled 5 Normal operation Factory adjustment when this switch is on temperature delays are eliminated and solar temperature is displayed Do not leave this switch in the ON position 6 Spare Aux...

Страница 31: ...No change 4 Heater cool down operates Heater cool down disabled 5 Normal operation Factory adjustment when this switch is on temperature delays are eliminated and solar temperature is displayed Do not...

Страница 32: ...er 1 Sprinkler 2 Sprinkler 3 Stereo Stream Swim Jet Timed Aux Valve s Wtr Feature Whirlpool 1 2 3 Back Basement Beach Bedroom Bug Cabana Color Wheel Deck Dock Drive East Entry Equipment Fan Fence Floo...

Страница 33: ...Page 33 NOTES...

Страница 34: ...Page 34 NOTES...

Страница 35: ......

Страница 36: ...r r r r Litho in U S A Waterpik Technologies 0504 H0572200 ETL LISTED CONFORMS TO UL STD 1563 CERTIFIED TO CAN CSA C22 2 NO 218 1 PDA HANDHELD REMOTE FCC ID S8F826X PDA TRANSCEIVER FCC ID S8F8252...

Отзывы: