5. Parts List

The following table is for your reference. To 

order additional parts, please contact your local Jandy 
distributor.

ITEM 

NO.

COMPONENT DESCRIPTION

R0412001

R0412003

R0412005

1

uC1 CONTROL uNIT

1

1

1

2

HS1 POwER vENTER (bLOwER)

1

-

-

3

HS2 POwER vENTER  (bLOwER)

-

1

1

4

vH1-4 4” vENT HOOD

1

-

-

5

vH1-6 6” vENT HOOD

-

1

1

6

vENT REDuCER (5” X 4” FOR MODEL 125) 

1

-

-

7

vENT REDuCER (6” X 4” FOR MODEL 175)

1

-

-

8

vENT REDuCER (7” X 6” FOR MODEL 250)

-

1

-

9

vENT REDuCER (8” X 6” FOR MODEL 325)

-

-

1

10

vENT REDuCER (9” X 6” FOR MODEL 400)

-

-

1

11

wIRE NuTS 

3

3

3

12

YELLOw wIRE aSSEMbLY  (MODEL LD ONLY)

1

1

1

13

PuRPLE wIRE aSSEMbLY

1

1

1

14

1/4” DOubLE MaLE X 1/4” FEMaLE CONNECTOR 

(MODEL LD ONLY)

1

1

1

15

bLOwER RELaY (MODEL LJ ONLY)

1

1

1

16

bLOwER RELaY bRaCKET (MODEL LJ wITH PuMP 

RELaY ONLY)

1

1

1

17

SCREwS (#6-20 X 1/2”) RELaY MOuNTING (MODEL LJ 

wITH PuMP RELaY ONLY)

2

2

2

18

aIR DEFLECTOR bRaCKET (MODEL LJ ONLY)

1

1

1

19

LD/POwER vENTER wIRING DIaGRaM LabEL (MOD-

EL LJ ONLY)

1

1

1

20

LJ/POwER vENTER wIRING DIaGRaM LabEL (MOD-

EL LJ ONLY)

1

1

1

QUANTITY

H0275000D

Zodiac Pool Systems, Inc.

6000 Condor Drive, Moorpark, Ca, uSa 93021 

 800.822.7933 

 FaX 877.327.1403

 

 

Litho in u.S.a. © Zodiac Pool Systems, Inc. 1005

Содержание R0412001

Страница 1: ...u with all of the major compo nents of the system that you will need to install the side wall vent Due to the different possible configurations for venting we do not supply the vent pipe elbows tees w...

Страница 2: ...nfiguration consists of an initial vertical section of vent pipe see Figure 2 Either configuration must meet the following constraints 1 The draft hood must be connected directly to the heater as per...

Страница 3: ...he heater with power 2 Remove the heater door 3 Locate the common terminal on the transformer There will be a yellow wire with a piggy back terminal attached to the transformer and a green wire with a...

Страница 4: ...mp relay over the bracket and use the screws removed earlier to secure the bracket and the pump relay to the back panel see Figure 6 Figure 3 Remove the Cover of the High Voltage Assembly Figure 4 Mou...

Страница 5: ...or bracket included in the kit must be installed to deflect the air around the igniter allowing it to heat enough to ignite the gas The air deflector bracket is not needed on the mod el LD heater beca...

Страница 6: ...he side of the heater using a conduit connector and nut 3 Strip the insulation from each of the wires that will lead to the UC1 controller about 1 2 from the end 4 Locate the yellow wire installed on...

Страница 7: ...LD LJ Side Wall Vent Kit Instructions Page 7 Figure 10 Wiring Diagram for Connecting a Model LD Heater to a Side Wall Power Venter F2 F1...

Страница 8: ...Page 8 Figure 11 Wiring Diagram for Connecting a Model LJ Heater to a Side Wall Power Venter...

Страница 9: ...ler NOTE Power connection to the controller requires a three 3 conductor copper wire harness that is run in a conduit from the power supply to the con troller These components must be supplied by the...

Страница 10: ...tch es must remain in the off down position see Figure 12 3 5 2 Jumper Placement in the UC1 Controller Installed on a Model LD Heater The Jandy LD heater uses a 24V signal to activate the power venter...

Страница 11: ...peration and enables the heater to begin its ignition se quence 3 When the igniter is hot enough the gas valve opens and burner ignition takes place 4 When the call for heat ends the burners are shut...

Страница 12: ...EDUCER 9 X 6 FOR MODEL 400 1 11 WIRE NUTS 3 3 3 12 YELLOW WIRE ASSEMBLY MODEL LD ONLY 1 1 1 13 PURPLE WIRE ASSEMBLY 1 1 1 14 1 4 DOUBLE MALE X 1 4 FEMALE CONNECTOR MODEL LD ONLY 1 1 1 15 BLOWER RELAY...

Отзывы: